Literature DB >> 23726126

Reduction of contrast medium volume in abdominal aorta CTA: multiphasic injection technique versus a test bolus volume.

Wouter H Nijhof1, Charlotte S van der Vos, Bauke Anninga, Gerrit J Jager, Matthieu J C M Rutten.   

Abstract

OBJECTIVE: The purpose of this study is to reduce the administered contrast medium volume in abdominal CTA by using a test bolus injection, with the preservation of adequate quantitative and qualitative vessel enhancement. STUDY
DESIGN: For this technical efficacy study 30 patients, who were referred for a CTA examination of the abdominal aorta, were included. Randomly 15 patients were assigned to undergo a multiphasic injection protocol and received 89 mL of contrast medium (Optiray 350) (protocol I). Fifteen patients were assigned to the test bolus injection protocol (protocol II), which implies injection of a 10 mL test bolus of Optiray 350 prior to performing CTA with a 40 mL of contrast medium. Quantitative assessment of vascular enhancement was performed by measuring the amount of Hounsfield Units in the aorta at 30 positions from the celiac trunk to the iliac arteries in both groups. Qualitative assessment was performed by three radiologists who scored the images at a 5-point scale.
RESULTS: Quantitative assessment showed that there was no significant difference in vascular enhancement for patients between the two protocols, with mean attenuation values of 280.9 ± 50.84 HU and 258.60 ± 39.28 HU, respectively. The image quality of protocol I was rated 4.31 (range: 3.67/5.00) and of protocol II 4.11 (range: 2.67/5.00). These differences were not statistically significant.
CONCLUSION: This study showed that by using a test bolus injection and the administration of 50 mL of contrast medium overall, CTA of the abdominal aorta can reliably be performed, with regard to quantitative and qualitative adequate vessel enhancement.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Abdominal aorta; CT angiography; Image quality; Iodinated contrast medium; Test bolus injection

Mesh:

Substances:

Year:  2013        PMID: 23726126     DOI: 10.1016/j.ejrad.2013.03.027

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  3 in total

1.  Contrast Volume for Preoperative CT Angiography of the Aorta Based on Patient Heart Rate and Body Surface Area: A Pilot Study.

Authors:  Dominic Raymakers; Adriana Dubbeldam; Walter Coudyzer; Hilde Bosmans; Geert Maleux
Journal:  J Belg Soc Radiol       Date:  2019-10-04       Impact factor: 1.894

2.  Dual Energy CT Angiography of Peripheral Arterial Disease: Feasibility of Using Lower Contrast Medium Volume.

Authors:  Abdulrahman Almutairi; Zhonghua Sun; Abduljaleel Poovathumkadavi; Tarek Assar
Journal:  PLoS One       Date:  2015-09-29       Impact factor: 3.240

3.  Feasibility of low contrast media volume in CT angiography of the aorta.

Authors:  Anna Seehofnerová; Madeleine Kok; Casper Mihl; Dave Douwes; Anni Sailer; Estelle Nijssen; Michiel J W de Haan; Joachim E Wildberger; Marco Das
Journal:  Eur J Radiol Open       Date:  2015-04-28
  3 in total