Hidekazu Osada1, Hidemasa Shimpo, Tohru Hayakawa, Chikahiro Ohkubo.
Abstract
Thermoplastic resin clasps have been used for esthetic denture rehabilitation. However, details of the design of the clasps have never been thoroughly clarified. This study investigated the retentive forces of thermoplastic resin clasps for non-metal clasp dentures. The retentive forces of all thermoplastic resin clasps depended on the elastic modulus of each resin, undercuts, thickness, and widths of the tested. A clasp with more than 0.5 mm undercut and 1.0 mm thickness is needed for Valplast. Similarly, more than 0.25 mm undercut and 1.0 mm thickness and 0.5 mm undercut and 0.5 mm thickness are required for Estheshot and Reigning, respectively; thus, the recommended clasp arm thickness is 1.0 mm to 1.5 mm for Valplast and Estheshot and 0.5 mm to 1.0 mm for Reigning when the width of the retentive arm is 5.0 mm.Mesh: