Influence of thickness and undercut of thermoplastic resin clasps on retentive force.

Hidekazu Osada1, Hidemasa Shimpo, Tohru Hayakawa, Chikahiro Ohkubo.   

Abstract

Thermoplastic resin clasps have been used for esthetic denture rehabilitation. However, details of the design of the clasps have never been thoroughly clarified. This study investigated the retentive forces of thermoplastic resin clasps for non-metal clasp dentures. The retentive forces of all thermoplastic resin clasps depended on the elastic modulus of each resin, undercuts, thickness, and widths of the tested. A clasp with more than 0.5 mm undercut and 1.0 mm thickness is needed for Valplast. Similarly, more than 0.25 mm undercut and 1.0 mm thickness and 0.5 mm undercut and 0.5 mm thickness are required for Estheshot and Reigning, respectively; thus, the recommended clasp arm thickness is 1.0 mm to 1.5 mm for Valplast and Estheshot and 0.5 mm to 1.0 mm for Reigning when the width of the retentive arm is 5.0 mm.

Mesh:

Substances:

Year:  2013        PMID: 23718997     DOI: 10.4012/dmj.2012-284

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  5 in total

1.  Wear resistance of injection-molded thermoplastic denture base resins.

Authors:  Ippei Hamanaka; Misa Iwamoto; Lippo V J Lassila; Pekka K Vallittu; Yutaka Takahashi
Journal:  Acta Biomater Odontol Scand       Date:  2016-01-26

2.  Different Materials Used as Denture Retainers and Their Colour Stability.

Authors:  Sherif A Sadek; Wessam M Dehis; Hala Hassan
Journal:  Open Access Maced J Med Sci       Date:  2018-11-15

3.  Comparative Study Clarifying the Most Suitable Material to Be Used as Partial Denture Clasps.

Authors:  Sherif Aly Sadek; Wessam Mohamed Dehis; Hala Hassan
Journal:  Open Access Maced J Med Sci       Date:  2018-06-07

Review 4.  Nonmetal clasp dentures: What is the evidence about their use?

Authors:  Inti Mendoza-Carrasco; Juliana Hotta; Carolina Yoshi Campos Sugio; Andréa Lemos Falcao Procópio; Vanessa Migliorini Urban; Victor Mosquim; Gerson Aparecido Foratori-Junior; Simone Soares; Karin Hermana Neppelenbroek
Journal:  J Indian Prosthodont Soc       Date:  2020-07-17

5.  Is the high-performance thermoplastic polyetheretherketone indicated as a clasp material for removable dental prostheses?

Authors:  Danka Micovic; Felicitas Mayinger; Sebastian Bauer; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2020-10-07       Impact factor: 3.573

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.