Literature DB >> 23718822

Effects of open-irrigated radiofrequency ablation catheter design on lesion formation and complications: in vitro comparison of 6 different devices.

Jose M Guerra1, Esther Jorge, Silvia Raga, Carolina Gálvez-Montón, Concepción Alonso-Martín, Enrique Rodríguez-Font, Juan Cinca, Xavier Viñolas.   

Abstract

INTRODUCTION: Open-irrigated radiofrequency ablation catheters with slight differences in tip architecture are widely used, although limited comparative data are available. The purpose of this study was to compare the lesion size and potential complications produced by commercially available open-irrigated catheters in an in vitro porcine heart model. METHODS AND
RESULTS: Six catheters were tested (Biosense Webster Thermocool, Boston Scientific Open irrigated, St. Jude CoolPath, St. Jude CoolPath Duo, Biosense Webster Thermocool SF, St. Jude Cool Flex) at 20 and 35 W power-control, under 2 different blood flows (0.1 and 0.5 m/s) and at 2 target durations (30 and 60 seconds). A total of 601 lesions were made in 26 in vitro preparations. The tip temperature profile showed significant differences between the catheters (P < 0.001) with the Thermocool SF registering the lowest. Only the surface diameter and the depth at maximum diameter of the lesion were influenced by the design of the ablation electrode. The lesion volume did not show significant differences between catheters for any power, application duration or blood flow condition. Char and pops occurred more often at 35 W with only slight differences between the catheters.
CONCLUSIONS: Tip design of the 6 different irrigated catheters does not affect the lesion total volume, although a slight difference in lesion geometry in terms of surface diameter and depth at maximum diameter is present. The catheters show a slight different in vitro safety profile.
© 2013 Wiley Periodicals, Inc.

Keywords:  atrial fibrillation; catheter ablation; irrigated catheter; lesion size; radiofrequency ablation

Mesh:

Year:  2013        PMID: 23718822     DOI: 10.1111/jce.12175

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  15 in total

1.  Novel catheter enabling simultaneous radiofrequency ablation and optical coherence reflectometry.

Authors:  D Herranz; Juan Lloret; Santiago Jiménez-Valero; J L Rubio-Guivernau; Eduardo Margallo-Balbás
Journal:  Biomed Opt Express       Date:  2015-08-07       Impact factor: 3.732

2.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Saenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  J Interv Card Electrophysiol       Date:  2020-10       Impact factor: 1.900

3.  Left atrial anterior line ablation using ablation index and inter-lesion distance measurement.

Authors:  Francesco Santoro; Andreas Metzner; Natale Daniele Brunetti; Christian-H Heeger; Shibu Mathew; Bruno Reissmann; Christine Lemeš; Tilman Maurer; Thomas Fink; Laura Rottner; Osamu Inaba; Karl-Heinz Kuck; Feifan Ouyang; Andreas Rillig
Journal:  Clin Res Cardiol       Date:  2019-02-02       Impact factor: 5.460

4.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Sáenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  Europace       Date:  2019-08-01       Impact factor: 5.214

Review 5.  Improvements In AF Ablation Outcome Will Be Based More On Technological Advancement Versus Mechanistic Understanding.

Authors:  Chen-Yang Jiang Md; Ru-Hong Jiang Ms
Journal:  J Atr Fibrillation       Date:  2014-08-31

6.  Impact of number of co-existing rotors and inter-electrode distance on accuracy of rotor localization.

Authors:  Konstantinos N Aronis; Hiroshi Ashikaga
Journal:  J Electrocardiol       Date:  2017-09-01       Impact factor: 1.438

7.  Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.

Authors:  Ahmed I Elbatran; Anthony Li; Mark M Gallagher; Riyaz Kaba; Mark Norman; Elijah R Behr; Manav Sohal; Abhay Bajpai; Zia Zuberi; Magdi M Saba
Journal:  J Interv Card Electrophysiol       Date:  2020-05-21       Impact factor: 1.900

8.  Temperature-Controlled Catheter Ablation for Paroxysmal Atrial Fibrillation: the QDOT-MICRO Workflow Sttudy.

Authors:  Tom De Potter; Massimo Grimaldi; Henrik Kjaerulf Jensen; Josef Kautzner; Petr Neuzil; Johan Vijgen; Andrea Natale; Steen Buus Kristiansen; Peter Lukac; Petr Peichl; Vivek Y Reddy
Journal:  J Atr Fibrillation       Date:  2021-04-30

9.  Impact of Variableorientation and Flow Rates on Radiofrequency Ablation Lesions Created by Externally Irrigated Catheters: An Ex-Vivo Study.

Authors:  Nishaki Mehta; Katerina Morgaenko; William Sauer; William Stevenson; David Haines
Journal:  J Atr Fibrillation       Date:  2020-10-31

10.  Computational Modeling of Open-Irrigated Electrodes for Radiofrequency Cardiac Ablation Including Blood Motion-Saline Flow Interaction.

Authors:  Ana González-Suárez; Enrique Berjano; Jose M Guerra; Luca Gerardo-Giorda
Journal:  PLoS One       Date:  2016-03-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.