Literature DB >> 23718611

Magnetothermoacoustics from magnetic nanoparticles by short bursting or frequency chirped alternating magnetic field: a theoretical feasibility analysis.

Daqing Piao1, Rheal A Towner, Nataliya Smith, Wei R Chen.   

Abstract

PURPOSE: To propose an alternative method of thermoacoustic wave generation based on heating of magnetic nanoparticles (MNPs) using alternating magnetic field (AMF).
METHODS: The feasibility of thermoacoustic wave generation from MNPs by applying a short-burst of AMF or a frequency-modulated AMF is theoretically analyzed. As the relaxation of MNPs is strongly dependent upon the amplitude and frequency of AMF, either an amplitude modulated, fixed frequency AMF (termed time-domain AMF) or a frequency modulated, constant amplitude AMF (termed frequency-domain AMF) will result in time-varying heat dissipation from MNPs, which has the potential to generate thermoacoustic waves. Following Rosensweig's model of specific power loss of MNPs in a steady-state AMF, the time-resolved heat dissipations of MNPs of superparamagnetic size when exposed to a short bursting of AMF and∕or to a linearly frequency chirped AMF are derived, and the resulted acoustic propagation is presented. Based on experimentally measured temperature-rise characteristics of a superparamagnetic iron-oxide nanoparticle (SPION) matrix in a steady-state AMF of various frequencies, the heat dissipations of the SPION under time-domain and frequency-domain AMF configurations that could have practical utility for thermoacoustic wave generation are estimated.
RESULTS: The initial rates of the temperature-rise of the SPION matrix were measured at an iron-weight concentration of 0.8 mg∕ml and an AMF frequency of 88.8 kHz to 1.105 MHz. The measured initial rates of temperature-rise were modeled by Rosensweig's theory, and projected to 10 MHz AMF frequency, at which a 1 μs bursting corresponding to a 1.55 mm axial resolution of acoustic detection could contain 10 complete cycles of AMF oscillation and the power dissipation is approximately 84 times of that at 1 MHz. Exposing the SPION matrix to a 1 μs bursting of AMF at 10 MHz frequency and 100 Oe field intensity would produce a volumetric heat dissipation of 7.7 μJ∕cm(3) over the microsecond duration of the AMF burst. If the SPION matrix is exposed to a 1 ms long AMF train at 100 Oe field intensity that chirps linearly from 1 to 10 MHz, the volumetric heat dissipation produced over each 2π phase change of the AMF oscillation is estimated to increase from 0.15 to 1.1 μJ∕cm(3) within the millisecond duration of the chirping of AMF.
CONCLUSIONS: The heat dissipations upon SPION (∼1 mg∕ml iron-weight concentration) by a 1 μs bursting of 100 Oe AMF at 10 MHz and a 1 ms train of 100 Oe AMF that chirps linearly from 1 to 10 MHz were estimated to determine the potential of thermal-acoustic wave generation. Although thermoacoustic wave generation from MNPs by time- or frequency-domain AMF applications is predicted, the experimental generation of such a wave remains challenging.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23718611      PMCID: PMC3669145          DOI: 10.1118/1.4804056

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  27 in total

1.  Thermoacoustic computed tomography--technical considerations.

Authors:  R A Kruger; D R Reinecke; G A Kruger
Journal:  Med Phys       Date:  1999-09       Impact factor: 4.071

2.  Magnetoacoustic imaging of magnetic iron oxide nanoparticles embedded in biological tissues with microsecond magnetic stimulation.

Authors:  Gang Hu; Bin He
Journal:  Appl Phys Lett       Date:  2012-01-06       Impact factor: 3.791

3.  Quantitative microwave-induced thermoacoustic tomography.

Authors:  Lei Yao; Gaofeng Guo; Huabei Jiang
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

4.  Magnetoacoustic tomography with magnetic induction (MAT-MI).

Authors:  Yuan Xu; Bin He
Journal:  Phys Med Biol       Date:  2005-10-19       Impact factor: 3.609

5.  Thermoacoustic molecular tomography with magnetic nanoparticle contrast agents for targeted tumor detection.

Authors:  Liming Nie; Zhongmin Ou; Sihua Yang; Da Xing
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

6.  Microwave-induced thermoacoustic scanning CT for high-contrast and noninvasive breast cancer imaging.

Authors:  Liming Nie; Da Xing; Quan Zhou; Diwu Yang; Hua Guo
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

Review 7.  Magnetic nanomaterials for hyperthermia-based therapy and controlled drug delivery.

Authors:  Challa S S R Kumar; Faruq Mohammad
Journal:  Adv Drug Deliv Rev       Date:  2011-04-05       Impact factor: 15.470

8.  Targeting of primary breast cancers and metastases in a transgenic mouse model using rationally designed multifunctional SPIONs.

Authors:  Forrest M Kievit; Zachary R Stephen; Omid Veiseh; Hamed Arami; Tingzhong Wang; Vy P Lai; James O Park; Richard G Ellenbogen; Mary L Disis; Miqin Zhang
Journal:  ACS Nano       Date:  2012-02-22       Impact factor: 15.881

Review 9.  Application of hyperthermia induced by superparamagnetic iron oxide nanoparticles in glioma treatment.

Authors:  André C Silva; Tiago R Oliveira; Javier B Mamani; Suzana M F Malheiros; Luciana Malavolta; Lorena F Pavon; Tatiana T Sibov; Edson Amaro; Alberto Tannús; Edson L G Vidoto; Mateus J Martins; Ricardo S Santos; Lionel F Gamarra
Journal:  Int J Nanomedicine       Date:  2011-03-25

10.  Iron oxide nanoparticles induce human microvascular endothelial cell permeability through reactive oxygen species production and microtubule remodeling.

Authors:  Patrick L Apopa; Yong Qian; Rong Shao; Nancy Lan Guo; Diane Schwegler-Berry; Maricica Pacurari; Dale Porter; Xianglin Shi; Val Vallyathan; Vincent Castranova; Daniel C Flynn
Journal:  Part Fibre Toxicol       Date:  2009-01-09       Impact factor: 9.400

View more
  4 in total

1.  Erratum: Magneto-thermo-acoustics from magnetic nanoparticles by short bursting or frequency chirped alternating magnetic field: a theoretical feasibility analysis. Med. Phys. 40(6): p. 063301 (2013).

Authors:  Daqing Piao; Rheal A Towner; Nataliya Smith; Wei R Chen
Journal:  Med Phys       Date:  2019-08-04       Impact factor: 4.071

2.  Looking at sound: optoacoustics with all-optical ultrasound detection.

Authors:  Georg Wissmeyer; Miguel A Pleitez; Amir Rosenthal; Vasilis Ntziachristos
Journal:  Light Sci Appl       Date:  2018-08-15       Impact factor: 17.782

Review 3.  Magnetic mediators for ultrasound theranostics.

Authors:  Arkadiusz Józefczak; Katarzyna Kaczmarek; Rafał Bielas
Journal:  Theranostics       Date:  2021-11-02       Impact factor: 11.556

Review 4.  Electromagnetic⁻Acoustic Sensing for Biomedical Applications.

Authors:  Siyu Liu; Ruochong Zhang; Zesheng Zheng; Yuanjin Zheng
Journal:  Sensors (Basel)       Date:  2018-09-21       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.