PURPOSE:Coronary angiography using multidetector computed tomography (MDCT-CA) is a recent technique for the nonivasive study of coronary arteries. This study assessed the diagnostic accuracy of coronary artery stenosis evaluation obtained by three readers at different levels of training or at different points of the learning curve proposed by the international guidelines. MATERIALS AND METHODS: Three radiologists in training with different levels of experience in MDCT-CA scored 50 cases at various time points of the learning curve: baseline, 4 weeks, 8 weeks and 6 months. The trainee radiologists evaluated the degree of stenosis on each coronary segment, and overall accuracy was calculated on a per-segment, pervessel and per-patient basis. RESULTS: All readers improved analysis accuracy per segment (range, 73-90%); sensitivity reached 45% per segment, 84% per vessel and 93% per patient; specificity was 99% per segment and vessel and 98% per patient. Positive and negative predictive values increased to 94% and 92%, respectively. CONCLUSIONS: Although all readers improved in diagnostic performance with growing experience with MDCT-CA, a longer training period may be necessary to achieve adequate levels of expertise in MDCT-CA to be able to perform as independent readers.
RCT Entities:
PURPOSE: Coronary angiography using multidetector computed tomography (MDCT-CA) is a recent technique for the nonivasive study of coronary arteries. This study assessed the diagnostic accuracy of coronary artery stenosis evaluation obtained by three readers at different levels of training or at different points of the learning curve proposed by the international guidelines. MATERIALS AND METHODS: Three radiologists in training with different levels of experience in MDCT-CA scored 50 cases at various time points of the learning curve: baseline, 4 weeks, 8 weeks and 6 months. The trainee radiologists evaluated the degree of stenosis on each coronary segment, and overall accuracy was calculated on a per-segment, pervessel and per-patient basis. RESULTS: All readers improved analysis accuracy per segment (range, 73-90%); sensitivity reached 45% per segment, 84% per vessel and 93% per patient; specificity was 99% per segment and vessel and 98% per patient. Positive and negative predictive values increased to 94% and 92%, respectively. CONCLUSIONS: Although all readers improved in diagnostic performance with growing experience with MDCT-CA, a longer training period may be necessary to achieve adequate levels of expertise in MDCT-CA to be able to perform as independent readers.
Authors: S Achenbach; S Ulzheimer; U Baum; M Kachelriess; D Ropers; T Giesler; W Bautz; W G Daniel; W A Kalender; W Moshage Journal: Circulation Date: 2000-12-05 Impact factor: 29.690
Authors: Allen J Taylor; Manuel Cerqueira; John McB Hodgson; Daniel Mark; James Min; Patrick O'Gara; Geoffrey D Rubin; Christopher M Kramer; Daniel Berman; Alan Brown; Farooq A Chaudhry; Ricardo C Cury; Milind Y Desai; Andrew J Einstein; Antoinette S Gomes; Robert Harrington; Udo Hoffmann; Rahul Khare; John Lesser; Christopher McGann; Alan Rosenberg; Robert Schwartz; Marc Shelton; Gerald W Smetana; Sidney C Smith Journal: J Am Coll Cardiol Date: 2010-11-23 Impact factor: 24.094
Authors: Stephen Schroeder; Stephan Achenbach; Frank Bengel; Christof Burgstahler; Filippo Cademartiri; Pim de Feyter; Richard George; Philipp Kaufmann; Andreas F Kopp; Juhani Knuuti; Dieter Ropers; Joanne Schuijf; Laurens F Tops; Jeroen J Bax Journal: Eur Heart J Date: 2007-12-15 Impact factor: 29.983
Authors: Francesca Pugliese; M G Myriam Hunink; Katarzyna Gruszczynska; Filippo Alberghina; Roberto Malagó; Niels van Pelt; Nico R Mollet; Filippo Cademartiri; Annick C Weustink; Willem B Meijboom; Cilia L M Witteman; Pim J de Feyter; Gabriel P Krestin Journal: Radiology Date: 2009-05 Impact factor: 11.105
Authors: Koen Nieman; Filippo Cademartiri; Pedro A Lemos; Rolf Raaijmakers; Peter M T Pattynama; Pim J de Feyter Journal: Circulation Date: 2002-10-15 Impact factor: 29.690
Authors: E Maffei; A Palumbo; C Martini; A Cuttone; F Ugo; E Emiliano; A Menozzi; L Vignali; V Brambilla; P Coruzzi; A Weustink; N Mollet; D Ardissino; C Reverberi; G Crisi; F Cademartiri Journal: Radiol Med Date: 2009-11-09 Impact factor: 3.469
Authors: Francesca Pugliese; Nico R Mollet; M G Myriam Hunink; Filippo Cademartiri; Koen Nieman; Ron T van Domburg; Willem B Meijboom; Carlos Van Mieghem; Annick C Weustink; Marcel L Dijkshoorn; Pim J de Feyter; Gabriel P Krestin Journal: Radiology Date: 2008-01-07 Impact factor: 11.105
Authors: Filippo Cademartiri; Ludovico La Grutta; Roberto Malagò; Filippo Alberghina; Willem B Meijboom; Francesca Pugliese; Erica Maffei; Anselmo Alessandro Palumbo; Annachiara Aldrovandi; Michele Fusaro; Valerio Brambilla; Paolo Coruzzi; Massimo Midiri; Nico R A Mollet; Gabriel P Krestin Journal: Eur Radiol Date: 2008-02-02 Impact factor: 5.315