Literature DB >> 2371595

Verification of sleep apnea using a portable sleep apnea screening device.

H A Emsellem1, W A Corson, B A Rappaport, S Hackett, L G Smith, J N Hausfeld.   

Abstract

Sixty-seven patients referred to a sleep laboratory with a tentative diagnosis of obstructive sleep apnea were examined with a device designed for home use as an apnea screening system. Direct comparison was made between data obtained by the portable device and by data acquired simultaneously with standard polysomnographic techniques. The portable recorder measured nasal/oral airflow, chest wall movement, cardiac rhythm, and blood oxygen saturation. There was no significant difference in the number of disordered breathing events (apneas and hypopneas) recorded by the two systems. The portable device was found to have a sensitivity of 95% and a specificity of 96%. Indications and limitations for use of the portable home apnea screening test are reviewed and guidelines for normalcy suggested.

Entities:  

Mesh:

Year:  1990        PMID: 2371595     DOI: 10.1097/00007611-199007000-00006

Source DB:  PubMed          Journal:  South Med J        ISSN: 0038-4348            Impact factor:   0.954


  6 in total

Review 1.  Management of obstructive sleep apnea in edentulous patients: an overview of the literature.

Authors:  David S P Heidsieck; Maurits H T de Ruiter; Jan de Lange
Journal:  Sleep Breath       Date:  2015-11-19       Impact factor: 2.816

2.  Timing, number and complexities of sleep studies.

Authors:  K P Strohl
Journal:  Sleep Breath       Date:  1997-06       Impact factor: 2.816

3.  Comparison of partially attended night time respiratory recordings and full polysomnography in patients with suspected sleep apnoea/hypopnoea syndrome.

Authors:  P Lloberes; J M Montserrat; A Ascaso; O Parra; A Granados; P Alonso; I Vilaseca; R Rodriguez-Roisin
Journal:  Thorax       Date:  1996-10       Impact factor: 9.139

4.  Negative association between self-reported jaw symptoms and apnea-hypopnea index in patients with symptoms of obstructive sleep apnea syndrome: a pilot study.

Authors:  Takafumi Kato; Akira Mikami; Hideko Sugita; Hisae Muraki; Mutsumi Okura; Motoharu Ohi; Mitsutaka Taniguchi
Journal:  Sleep Breath       Date:  2012-04-18       Impact factor: 2.816

5.  A prospective randomized study comparing two different degrees of mandibular advancement with a dental appliance in treatment of severe obstructive sleep apnea.

Authors:  Marie-Louise Walker-Engström; Ivar Ringqvist; Olle Vestling; Bo Wilhelmsson; Ake Tegelberg
Journal:  Sleep Breath       Date:  2003-09       Impact factor: 2.816

6.  Cheyne-Stokes respiration in patients hospitalised for heart failure.

Authors:  Lena Mared; Charles Cline; Leif Erhardt; Søren Berg; Bengt Midgren
Journal:  Respir Res       Date:  2004-09-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.