Literature DB >> 23714387

Iliotibial band irritation caused by the EndoButton after anatomic double-bundle anterior cruciate ligament reconstruction: report of two cases.

Shuji Taketomi1, Hiroshi Inui, Jinso Hirota, Kensuke Nakamura, Takaki Sanada, Hironari Masuda, Sakae Tanaka, Takumi Nakagawa.   

Abstract

Two patients underwent arthroscopic anatomic double-bundle anterior cruciate ligament (ACL) reconstruction using the EndoButton for femoral fixation. The femoral tunnels were created by the inside-out technique through a far anteromedial portal. The patients postoperatively developed moderate lateral knee pain without instability. At the second-look arthroscopic evaluation, the two EndoButtons were removed. Both patients were completely asymptomatic several months after implant removal, implying that the EndoButtons caused the mechanical irritation in the iliotibial band. This is the first report describing removal of EndoButtons because of pain caused by friction with the iliotibial band. In anatomic ACL reconstruction, if the femoral tunnel exit is positioned near the lateral femoral epicondyle, care should be taken to prevent iliotibial band friction syndrome that could result because of the EndoButton.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23714387     DOI: 10.1016/j.knee.2013.03.013

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  9 in total

1.  Secure fixation of femoral bone plug with a suspensory button in anatomical anterior cruciate ligament reconstruction with bone-patellar tendon-bone graft.

Authors:  Shuji Taketomi; Hiroshi Inui; Kensuke Nakamura; Ryota Yamagami; Keitaro Tahara; Takaki Sanada; Hironari Masuda; Sakae Tanaka; Takumi Nakagawa
Journal:  Joints       Date:  2016-01-28

2.  Arthroscopically confirmed femoral button deployment.

Authors:  Bertrand Sonnery-Cottet; Fernando C Rezende; Ayrton Martins Neto; Jean M Fayard; Mathieu Thaunat; Deiary F Kader
Journal:  Arthrosc Tech       Date:  2014-05-05

3.  Self-flip Technique of the TightRope RT Button for Soft-Tissue Anterior Cruciate Ligament Reconstruction.

Authors:  Kengo Harato; Yasuo Niki; Takashi Toyoda; Yusaku Kamata; Ko Masumoto; Toshiro Otani; Yasunori Suda
Journal:  Arthrosc Tech       Date:  2016-04-18

4.  Functional assessment of combined reconstruction of the anterior cruciate ligament and posterolateral corner with a single femoral tunnel: a two-year minimum follow-up.

Authors:  Camilo Partezani Helito; Marcelo Batista Bonadio; Marco Kawamura Demange; Roberto Freire da Mota e Albuquerque; José Ricardo Pécora; Gilberto Luis Camanho; Fabio Janson Angelini
Journal:  Int Orthop       Date:  2014-11-07       Impact factor: 3.075

5.  TightRope Versus Biocomposite Interference Screw for Fixation in Allograft ACL Reconstruction: Prospective Evaluation of Osseous Integration and Patient Outcomes.

Authors:  Shahram Shawn Yari; Ashraf N El Naga; Amar Patel; Ali Asaf Qadeer; Anup Shah
Journal:  JB JS Open Access       Date:  2020-04-02

6.  Confirming Proper Button Deployment of Suspensory Fixation During ACL Reconstruction.

Authors:  Daniel F O'Brien; Lilah Fones; Victoria Stoj; Cory Edgar; Katherine Coyner; Robert A Arciero
Journal:  Orthop J Sports Med       Date:  2021-01-19

7.  Lateral Knee Pain after Outside-in Anatomic Double-Bundle Anterior Cruciate Ligament Reconstruction Using the TightRope RT.

Authors:  Kohei Kawaguchi; So Kuribayashi; Shuichi Nakayama; Keisuke Nakazato; Toru Fukubayashi; Shuji Okinaga
Journal:  Knee Surg Relat Res       Date:  2016-02-29

8.  Arthroscopic Technique to Reduce Suture Button Migration During Anterior Cruciate Ligament Reconstruction Procedure.

Authors:  Yasuo Ohnishi; Angela Chang; Hajime Utsunomiya; Hitoshi Suzuki; Eiichiro Nakamura; Akinori Sakai; Soshi Uchida
Journal:  Arthrosc Tech       Date:  2017-10-23

9.  A Percutaneous Technique to Reposition the Cortical Button of Adjustable-Loop Devices in Anterior Cruciate Ligament Reconstruction.

Authors:  Dhananjaya Sabat; Rakesh Sehrawat; Vinod Kumar
Journal:  Arthrosc Tech       Date:  2019-10-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.