Literature DB >> 23714260

Orthodontic mini-implant stability under continuous or intermittent loading: a histomorphometric and biomechanical analysis.

Yeke Wu1, Zhenrui Xu, Luyuan Tan, Lijun Tan, Zhihe Zhao, Pu Yang, Yu Li, Tian Tang, Lixing Zhao.   

Abstract

BACKGROUND: Both continuous and intermittent loadings are commonly applied in orthodontics. Clinical experiences and some studies believed that longer duration of force produce more effect (tooth movement, suture expansion, bone remodeling) than transient forces applied with the same magnitude. Alternatively, others indicated that interruption or recovery periods of various periods between loadings cause more bone remodeling and less root resorption. Therefore, which force is more favorable for osseointegration and stability of orthodontic mini-implant remains to be elucidated.
PURPOSE: To evaluate the influence of continuous or intermittent loading on stability of titanium mini-implants.
MATERIALS AND METHODS: One hundred ninety-two mini-implants were implanted bilaterally in intraradicular zones of mandibular M1 and P2 in 48 beagles. Loadings were delivered consecutively in continuous group, pauses were given for the last 3 or 7 days of each 2-week reactivation period for intermittent group A and B, respectively. The group unloaded was set as control. After 2, 4, 6 and 8 weeks, the animals were sacrificed and microscopic computerized tomography (μCT), histomorphological observation and pull-out test were applied.
RESULTS: The μCT parameters of mini-implants in four groups were gradually increased with loading time prolonged, while the value of peak load at extraction (F(max)) increased and reached summit at week 6, but dropped slightly at week 8. In continuous group, all measurements were lower than those in intermittent groups at all time points (p < .05), and all values in intermittent group B were higher than those in intermittent group A. Histomorphology observation revealed different degrees of bone remodeling with new bone formation in the peri-implants region in different groups.
CONCLUSIONS: Intermittent loading regimen is more favorable for obtaining stability than continuous force.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  continuous force; intermittent force; mini-implants; osseointegration; stability

Mesh:

Substances:

Year:  2013        PMID: 23714260     DOI: 10.1111/cid.12090

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  1 in total

1.  Effects of monocortical and bicortical mini-implant anchorage on bone-borne palatal expansion using finite element analysis.

Authors:  Robert J Lee; Won Moon; Christine Hong
Journal:  Am J Orthod Dentofacial Orthop       Date:  2017-05       Impact factor: 2.650

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.