Literature DB >> 23713963

Impact of bone quality and implant type on the primary stability: an experimental study using bovine bone.

Sukumaran Anil1, Abdullah Alfarraj Aldosari.   

Abstract

The purpose of this in vitro study was to compare the primary stability and removal torque of bone level and tissue level implants in different bone qualities. Twenty tissue level and bone level implants (3.3 × 10 mm and 4.1 × 10 mm) were used for assessing the stability in type II and type IV bone. Forty bovine rib blocks were used in this study. The primary stability of the implant was measured by the resonance frequency using an Osstel device. The removal torque values (RTV) of the implants was assessed using a digital torque gauge instrument. The implant stability quotient (ISQ) values and the RTV showed a marginally higher stability with bone level implants as compared to tissue level implants. However, these differences were not statistically significant in both type of bone used (P > 0.05). On the other hand, compared to type IV, type II bone showed significant differences in the ISQ (P < 0.01) and RTV (P < 0.001) of bone level and tissue level implants. The study concluded that bone quality is an important factor in establishing primary stability than the implant dimension. Bone level and tissue level implants of same dimensions can be selected based on the esthetic demands since they showed similar mechanical properties.

Entities:  

Keywords:  implants; osseointegration; primary stability; removal torque; resonance frequency analysis

Mesh:

Substances:

Year:  2013        PMID: 23713963     DOI: 10.1563/AAID-JOI-D-11-00156

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  6 in total

1.  Dual Delivery of Alendronate and E7-BMP-2 Peptide via Calcium Chelation to Mineralized Nanofiber Fragments for Alveolar Bone Regeneration.

Authors:  Sunil Kumar Boda; Hongjun Wang; Johnson V John; Richard A Reinhardt; Jingwei Xie
Journal:  ACS Biomater Sci Eng       Date:  2020-03-20

2.  Non-destructive, spectrophotometric analysis of the thickness of the cell-multilayered periosteal sheet.

Authors:  Hachidai Aizawa; Takashi Uematsu; Atsushi Sato; Hideo Masuki; Hideo Kawabata; Tetsuhiro Tsujino; Kazushige Isobe; Yutaka Kitamura; Masaki Nagata; Koh Nakata; Tomoyuki Kawase
Journal:  Int J Implant Dent       Date:  2022-05-02

3.  Implant Stability of Biological Hydroxyapatites Used in Dentistry.

Authors:  Maria Piedad Ramírez Fernández; Sergio A Gehrke; Patricia Mazón; Jose L Calvo-Guirado; Piedad N De Aza
Journal:  Materials (Basel)       Date:  2017-06-12       Impact factor: 3.623

4.  Repeatability of the resonance frequency analysis values in implants with a new technology.

Authors:  M-C Díaz-Castro; A Falcao; P López-Jarana; C Falcao; J-V Ríos-Santos; A Fernández-Palacín; M Herrero-Climent
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2019-09-01

5.  Influence of Sports Intervention Based on K-Center Algorithm on Adolescent Obesity Metabolism and Bone Quality.

Authors:  Fengyu Wu; Li Li; Guowei Zhao; Zhipeng Li
Journal:  J Healthc Eng       Date:  2021-09-30       Impact factor: 2.682

6.  Implant Dentistry from One-Way Direction to the Reversibility of the Osseointegration.

Authors:  Eduardo Anitua
Journal:  Eur J Dent       Date:  2022-02-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.