Literature DB >> 23712291

Multiplexed electrokinetic sample fractionation, preconcentration and elution for proteomics.

Yujuan Hua1, Abebaw B Jemere, Jelena Dragoljic, D Jed Harrison.   

Abstract

Both 6 and 8-channel integrated microfluidic sample pretreatment devices capable of performing "in space" sample fractionation, collection, preconcentration and elution of captured analytes via sheath flow assisted electrokinetic pumping are described. Coatings and monolithic polymer beds were developed for the glass devices to provide cationic surface charge and anodal electroosmotic flow for delivery to an electrospray emitter tip. A mixed cationic ([2-(methacryloyloxy)ethyl] trimethylammonium chloride) (META) and hydrophobic butyl methacrylate-based monolithic porous polymer, photopolymerized in the 6- or 8-fractionation channels, was used to capture and preconcentrate samples. A 0.45 wt% META loaded bed generated comparable anodic electroosmotic flow to the cationic polymer PolyE-323 coated channel segments in the device. The balanced electroosmotic flow allowed stable electrokinetic sheath flow to prevent cross contamination of separated protein fractions, while reducing protein/peptide adsorption on the channel walls. Sequential elution of analytes trapped in the SPE beds revealed that the monolithic columns could be efficiently used to provide sheath flow during elution of analytes, as demonstrated for neutral carboxy SNARF (residual signal, 0.08% RSD, n = 40) and charged fluorescein (residual signal, 2.5% n = 40). Elution from monolithic columns showed reproducible performance with peak area reproducibility of ~8% (n = 6 columns) in a single sequential elution and the run-to-run reproducibility was 2.4-6.7% RSD (n = 4) for elution from the same bed. The demonstrated ability of this device design and operation to elute from multiple fractionation beds into a single exit channel for sample analysis by fluorescence or electrospray mass spectrometry is a crucial component of an integrated fractionation and assay system for proteomics.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23712291     DOI: 10.1039/c3lc50401h

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  6 in total

1.  Electroosmotic flow hysteresis for dissimilar ionic solutions.

Authors:  An Eng Lim; Chun Yee Lim; Yee Cheong Lam
Journal:  Biomicrofluidics       Date:  2015-04-09       Impact factor: 2.800

2.  Increasing local density and purity of molecules/bacteria on a sensing surface from diluted blood using 3D hybrid electrokinetics.

Authors:  I-Fang Cheng; Tzu-Ying Chen; Wen-Cheng Chao
Journal:  Biomicrofluidics       Date:  2016-06-08       Impact factor: 2.800

Review 3.  Advances in monoliths and related porous materials for microfluidics.

Authors:  Radim Knob; Vishal Sahore; Mukul Sonker; Adam T Woolley
Journal:  Biomicrofluidics       Date:  2016-05-04       Impact factor: 2.800

4.  On-line pre-treatment, separation, and nanoelectrospray mass spectrometric determinations for pesticide metabolites and peptides based on a modular microfluidic platform.

Authors:  Yinyin Hao; Yajing Bao; Xueying Huang; Yijun Hu; Bo Xiong
Journal:  RSC Adv       Date:  2018-11-28       Impact factor: 3.361

5.  Electroosmotic Flow in Microchannel with Black Silicon Nanostructures.

Authors:  An Eng Lim; Chun Yee Lim; Yee Cheong Lam; Rafael Taboryski
Journal:  Micromachines (Basel)       Date:  2018-05-11       Impact factor: 2.891

6.  Biofunctionalized self-propelled micromotors as an alternative on-chip concentrating system.

Authors:  Laura Restrepo-Pérez; Lluís Soler; Cynthia Martínez-Cisneros; Samuel Sánchez; Oliver G Schmidt
Journal:  Lab Chip       Date:  2014-08-21       Impact factor: 6.799

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.