Literature DB >> 23712068

Positive end-expiratory pressure during laparoscopy: cardiac and respiratory effects.

Andrea Russo1, Enrico Di Stasio, Alessandro Scagliusi, Francesca Bevilacqua, Maria Antonietta Isgrò, Riccardo Marana, Elisabetta Marana.   

Abstract

STUDY
OBJECTIVE: To determine the effect of positive end-expiratory pressure (PEEP) on the respiratory system and on cardiac function.
DESIGN: Prospective randomized study.
SETTING: Operating room. PATIENTS: 60 ASA physical status 1 women scheduled for pelvic laparoscopic surgery.
INTERVENTIONS: Patients were ventilated normally during surgery; PEEP was modified depending on patient group allocation. Group A was the control group and did not receive PEEP. Group B received PEEP 5 cmH2O and Group C received PEEP 10 cmH2O. MEASUREMENTS: Respiratory parameters measured were partial pressure of arterial oxygen (PaO2), partial pressure of carbon dioxide (PaCO2), and end-tidal carbon dioxide tension (ETCO2). Cardiac parameters measured were left ventricular end-diastolic volume index (LVEDVI), ie, ratio of LVEDV/body surface area (BSA; [LVEDVI = end-diastolic volume [EDV]/BSA); left ventricular (LV) systolic function, tricuspid annular plane systolic excursion (TAPSE), right ventricular (RV) fractional area change (FAC), RV dimensions in the apical 4-chamber view, tracing basal and mid-cavity minor dimensions and longitudinal dimension, cardiac index, systolic pulmonary artery pressure (PASP), and systolic RV pressure (RVSP). Respiratory and cardiac measurements were recorded at T0 (baseline); T1 (after anesthesia induction, before pneumoperitoneum induction); at 10 (T2), 20 (T3), and 30 (T4) minutes after CO2 insufflation; and at the end of surgery (T5). MAIN
RESULTS: Ventilation with PEEP at 10 cm H2O led to significant improvement in both respiratory and cardiac parameters. A reduction in pulmonary vascular resistance and enhanced washout of expiratory CO2 occurred. Ten and, to a lesser extent, 5 cm H2O of PEEP decreased LV stroke work.
CONCLUSIONS: Ventilation with PEEP (up to 10 cm H2O) recruits the hypoventilated areas of the lungs and reduces cardiac afterload.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Echocardiography; Gas exchange; Laparoscopy; Pneumoperitoneum; Positive end-expiratory pressure; Stroke work

Mesh:

Substances:

Year:  2013        PMID: 23712068     DOI: 10.1016/j.jclinane.2013.01.011

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  6 in total

1.  Pneumoperitoneum deteriorates intratidal respiratory system mechanics: an observational study in lung-healthy patients.

Authors:  Steffen Wirth; Andreas Biesemann; Johannes Spaeth; Stefan Schumann
Journal:  Surg Endosc       Date:  2016-06-20       Impact factor: 4.584

2.  Intelligent Algorithm-Based Echocardiography to Evaluate the Effect of Lung Protective Ventilation Strategy on Cardiac Function and Hemodynamics in Patients Undergoing Laparoscopic Surgery.

Authors:  Huijuan Wang; Chao Gong; Yi Zhang; Yun Wang; Xiaoli Wang; Xiao Zhao; Lianhua Chen; Shitong Li
Journal:  Comput Math Methods Med       Date:  2022-06-30       Impact factor: 2.809

3.  Laparoscopic versus Open Ovariectomy in Bitches: Changes in Cardiorespiratory Values, Blood Parameters, and Sevoflurane Requirements Associated with the Surgical Technique.

Authors:  Silvia Fernández-Martín; Victoria Valiño-Cultelli; Antonio González-Cantalapiedra
Journal:  Animals (Basel)       Date:  2022-06-02       Impact factor: 3.231

4.  Effect of Different Levels of Positive End-Expiratory Pressure (PEEP) on Respiratory Status during Gynecologic Laparoscopy.

Authors:  Simin Atashkhoei; Negin Yavari; Mahsa Zarrintan; Eisa Bilejani; Sina Zarrintan
Journal:  Anesth Pain Med       Date:  2020-04-18

5.  Small-Incision Laparoscopy-Assisted Surgery Under Abdominal Cavity Irrigation in a Porcine Model.

Authors:  Tatsuo Igarashi; Takuro Ishii; Tomohiko Aoe; Wen-Wei Yu; Yuma Ebihara; Hiroshi Kawahira; Shiro Isono; Yukio Naya
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2016-01-08       Impact factor: 1.878

6.  Cardiac output measured by transthoracic echocardiography and Swan-Ganz catheter. A comparative study in mechanically ventilated patients with high positive end-expiratory pressure.

Authors:  José Gorrasi; Arturo Pazos; Lucia Florio; Carlos Américo; Natalia Lluberas; Gabriel Parma; Ricardo Lluberas
Journal:  Rev Bras Ter Intensiva       Date:  2019 Oct-Dec
  6 in total