Clinical validation protocols for noninvasive blood pressure monitors and their recognition by regulatory authorities and professional organizations: rationale and considerations for a single unified protocol or standard.

Kim-Gau Ng1.   

Abstract

Standardized protocols for validating the clinical accuracy of noninvasive blood pressure (NIBP) monitors have been available since 1987. Some of them were developed by standards bodies and others by professional organizations. They have been well-tested through use and progressively improved through multiple revisions; however, many methodological differences exist between them. In addition, for the purpose of regulatory approval or marketing clearance, some protocols are recognized in some countries but not in others; thus, manufacturers have to validate their NIBP monitors to more than one protocol in order to market them worldwide. The use of different protocols not only makes it difficult to compare one device with another but also complicates the validation, regulatory approval, marketing, and public acceptance of NIBP monitors, creating undue burden on manufacturers and unnecessary confusion among users. There is a need for protocol developers, standards bodies, and regulatory authorities to work together to develop and agree on a single unified protocol or standard, one that builds on the strengths of the various protocols that have been developed so far. It is apparent that there is already a trend toward convergence of the various protocols into two protocols, namely, the ISO 81060-2:2009 standard and the 2010 European Society of Hypertension International Protocol. With further reconciliation and consensus, it should be possible to integrate the best features of the ISO, European Society of Hypertension, and other protocols, along with further improvements, into a single unified protocol or standard.

Entities:  

Mesh:

Year:  2013        PMID: 23709002     DOI: 10.1097/MBP.0b013e3283624b3b

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  2 in total

1.  A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study.

Authors:  Tessa S Schoot; Mariska Weenk; Tom H van de Belt; Lucien J L P G Engelen; Harry van Goor; Sebastian J H Bredie
Journal:  J Med Internet Res       Date:  2016-05-05       Impact factor: 5.428

2.  Validation of BP devices QardioArm® in the general population and Omron M6 Comfort® in type II diabetic patients according to the European Society of Hypertension International Protocol (ESH-IP).

Authors:  Mirna N Chahine; Jirar Topouchian; Parounak Zelveian; Zoya Hakobyan; Arevik Melkonyan; Alaa Azaki; Reem Diab; Aya Harb; Roland Asmar
Journal:  Med Devices (Auckl)       Date:  2017-12-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.