Literature DB >> 23708693

Fast and quantitative analysis of branched-chain amino acids in biological samples using a pillar array column.

Yanting Song1, Katsuya Takatsuki, Muneki Isokawa, Tetsushi Sekiguchi, Jun Mizuno, Takashi Funatsu, Shuichi Shoji, Makoto Tsunoda.   

Abstract

In this study, a fast and quantitative determination method for branched-chain amino acids (BCAAs), namely leucine, isoleucine, and valine, was developed using a pillar array column. A pillar array column with low-dispersion turns was fabricated on a 20 × 20-mm(2) microchip using multistep ultraviolet photolithography and deep reactive ion etching. The BCAAs were fluorescently labeled with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), followed by reversed-phase separation on the pillar array column. The NBD derivatives of the three BCAAs and an internal standard (6-aminocaproic acid) were separated in 100 s. The calibration curves for the NBD-BCAAs had good linearity in the range of 0.4-20 μM, using an internal standard. The intra- and interday precisions were found to be in the ranges of 1.42-3.80 and 2.74-6.97%, respectively. The accuracies for the NBD-BCAA were from 90.2 to 99.1%. The method was used for the analysis of sports drink and human plasma samples. The concentrations of BCAAs determined by the developed method showed good agreements with those determined using a conventional high-performance liquid chromatography system. As BCAAs are important biomarkers of some diseases, these results showed that the developed method could be a potential diagnostic tool in clinical research.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23708693     DOI: 10.1007/s00216-013-7034-7

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  A reliable LC-MS/MS method for the quantification of natural amino acids in mouse plasma: Method validation and application to a study on amino acid dynamics during hepatocellular carcinoma progression.

Authors:  Zhenzhen Liu; Mei-Juan Tu; Chao Zhang; Joseph L Jilek; Qian-Yu Zhang; Ai-Ming Yu
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2019-06-02       Impact factor: 3.205

2.  Advances in and prospects of microchip liquid chromatography.

Authors:  James P Grinias; Robert T Kennedy
Journal:  Trends Analyt Chem       Date:  2016 Jul-Aug       Impact factor: 12.296

3.  Amino Acid Profiling Study of Psidium guajava L. Leaves as an Effective Treatment for Type 2 Diabetic Rats.

Authors:  Chang Xu; Xin Li; Debin Zeng; Ying Liu; Yuhang Gao; Makoto Tsunoda; Shiming Deng; Xi Xie; Rong Wang; Lu-Shuang Li; Yanting Song; Yingxia Zhang
Journal:  Evid Based Complement Alternat Med       Date:  2020-04-23       Impact factor: 2.629

4.  Improvement of an Automated Sample Injection System for Pillar Array Columns to Increase Analytical Reproducibility.

Authors:  Hiroshi Kuroki; Hirotaka Koyama; Makoto Tsunoda
Journal:  Molecules       Date:  2022-07-23       Impact factor: 4.927

Review 5.  Determination of amino acids in human biological fluids by high-performance liquid chromatography: critical review.

Authors:  Grażyna Gałęzowska; Joanna Ratajczyk; Lidia Wolska
Journal:  Amino Acids       Date:  2021-05-24       Impact factor: 3.520

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.