Literature DB >> 2370654

Measurement of osteoclastic resorption pits with a tandem scanning microscope.

A Boyde1, C E Dillon, S J Jones.   

Abstract

The functional capacity of isolated osteoclasts is measured by determining the volume of bone or dentine which they can resorb in vitro when cultured on flat tissue slices. Previous SEM stereophotogrammetric evaluations showed that the measurement of total resorptive area per sample, number of pits per sample, area per pit, etc., may be insufficient and that the volume to area ratio may be of utmost importance. A new procedure for the 3-D description and measurement of resorption pits using confocal microscopy has been established. Osteoclasts were cultured on slices of dentine which were prepared as for SEM. They were imaged with a Tracor Northern TSM equipped with piezo-electric translators for the objective lens focusing motion, interfaced to a TN8500 computer, using a TV camera for image transfer. The procedure consisted of generating a zeta map image of the focus depth at which maximum brightness was found at each pixel. Constructing binary masks corresponding to (i) the edge of the resorption pit to define the area beneath which the volume is to be calculated, and (ii) a uniform width at a small distance outside the edge of the pit, enabled the average height of the original surface to be measured and the slice above the pit to be subtracted. After subtraction of the volume element which lay above the top of the original specimen surface, the zeta map is a measure of both the area and volume of the pit.

Entities:  

Mesh:

Year:  1990        PMID: 2370654     DOI: 10.1111/j.1365-2818.1990.tb02999.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  4 in total

1.  Bovine deciduous dentine is more susceptible to osteoclastic resorption than permanent dentine: results of quantitative analyses.

Authors:  Bobby John Varghese; Kazuhiro Aoki; Hitoyata Shimokawa; Keiichi Ohya; Yuzo Takagi
Journal:  J Bone Miner Metab       Date:  2006       Impact factor: 2.626

2.  Pitfalls in pit measurement.

Authors:  A Boyde; S J Jones
Journal:  Calcif Tissue Int       Date:  1991-08       Impact factor: 4.333

3.  Endothelial cell adhesion in real time. Measurements in vitro by tandem scanning confocal image analysis.

Authors:  P F Davies; A Robotewskyj; M L Griem
Journal:  J Clin Invest       Date:  1993-06       Impact factor: 14.808

4.  Three-dimensional characterization of resorption cavity size and location in human vertebral trabecular bone.

Authors:  M G Goff; C R Slyfield; S R Kummari; E V Tkachenko; S E Fischer; Y H Yi; M G Jekir; T M Keaveny; C J Hernandez
Journal:  Bone       Date:  2012-04-03       Impact factor: 4.398

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.