Literature DB >> 23706504

A portable wireless near-infrared spatially resolved spectroscopy system for use on brain and muscle.

N L Everdell1, D Airantzis, C Kolvya, T Suzuki, C E Elwell.   

Abstract

We have designed, built and successfully tested a prototype portable and wireless near-infrared spectroscopy system. It takes forward the well-established series of NIRO spectroscopy instruments made by Hamamatsu Photonics (Hamamatsu City, Japan). It uses an identical optical probe, and has a data acquisition rate of 10 Hz. It illuminates the tissue with laser diode sources at 3 wavelengths of 775, 810 and 850 nm, and detects the reflected light with 2 silicon photodiode detectors at 2 different separations, enabling spatially resolved spectroscopy to be performed. We have tested it with both in vitro and in vivo experiments to establish its basic functionality for use in studies of both brain and muscle.
Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Near-infrared spectroscopy; Oximetry

Mesh:

Year:  2013        PMID: 23706504     DOI: 10.1016/j.medengphy.2013.04.011

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Bundled-Optode Method in Functional Near-Infrared Spectroscopy.

Authors:  Hoang-Dung Nguyen; Keum-Shik Hong; Yong-Il Shin
Journal:  PLoS One       Date:  2016-10-27       Impact factor: 3.240

Review 2.  Recent Progress in Wireless Sensors for Wearable Electronics.

Authors:  Young-Geun Park; Sangil Lee; Jang-Ung Park
Journal:  Sensors (Basel)       Date:  2019-10-09       Impact factor: 3.576

3.  Functional Near Infrared Spectroscopy: Enabling Routine Functional Brain Imaging.

Authors:  Meryem A Yücel; Juliette J Selb; Theodore J Huppert; Maria Angela Franceschini; David A Boas
Journal:  Curr Opin Biomed Eng       Date:  2017-10-06

Review 4.  Recent developments in near-infrared spectroscopy (NIRS) for the assessment of local skeletal muscle microvascular function and capacity to utilise oxygen.

Authors:  Siana Jones; Scott T Chiesa; Nishi Chaturvedi; Alun D Hughes
Journal:  Artery Res       Date:  2016-12       Impact factor: 0.597

Review 5.  Control Methods for Transradial Prostheses Based on Remnant Muscle Activity and Its Relationship with Proprioceptive Feedback.

Authors:  Stefan Grushko; Tomáš Spurný; Martin Černý
Journal:  Sensors (Basel)       Date:  2020-08-28       Impact factor: 3.576

  5 in total