Literature DB >> 23705577

Early single centre experience of flow diverting stents for the treatment of cerebral aneurysms.

Ahmed K Toma1, Fergus Robertson, Ken Wong, Yogish Joshi, Avinash Haridas, Joan Grieve, Laurence D Watkins, Neil D Kitchen, Stefan Brew.   

Abstract

INTRODUCTION: The flow diverting stent (FDS) is a relatively new endovascular therapeutic tool specifically designed to reconstruct the parent artery and divert blood flow along the normal anatomical course and away from the aneurysm neck and dome.
METHODS: Retrospective review of prospectively built clinical and imaging database of patients treated with FDS at the National Hospital for Neurology and Neurosurgery, Queen Square, London, UK was done.
RESULTS: Between 18/03/2008 and 10/11/2011, 80 patients underwent 84 FDS insertion procedures for various indications. Mean duration of clinical follow-up was 11.3 ± 9.3 months and of imaging follow-up was 10.6 ± 9.3 months. Sixty-seven had anterior circulation aneurysms while 17 had posterior circulation aneurysms. Seven (8.3%) patients died (two probably not related, giving a procedure-related mortality of 5.9%), eight had permanent new deficit (9.5%), 20 had transient deficit (23%) and 49 (58%) had no complications. There was a trend towards bad outcome with larger posterior circulation aneurysms. Angiographic follow-up showed 38% cure rate at 6 months and 61% at 12 months.
CONCLUSION: FDS should only be used following multidisciplinary discussion in selected patients. Further data is required regarding long-term safety, efficacy and indications.

Entities:  

Mesh:

Year:  2013        PMID: 23705577     DOI: 10.3109/02688697.2013.793292

Source DB:  PubMed          Journal:  Br J Neurosurg        ISSN: 0268-8697            Impact factor:   1.596


  6 in total

1.  Uncertainty and agreement regarding the role of flow diversion in the management of difficult aneurysms.

Authors:  T E Darsaut; J-C Gentric; C M McDougall; G Gevry; D Roy; A Weill; J Raymond
Journal:  AJNR Am J Neuroradiol       Date:  2015-01-15       Impact factor: 3.825

2.  Treatment of Unruptured Distal Anterior Circulation Aneurysms with Flow-Diverter Stents: A Meta-Analysis.

Authors:  F Cagnazzo; P Perrini; C Dargazanli; P-H Lefevre; G Gascou; R Morganti; D di Carlo; I Derraz; C Riquelme; A Bonafe; V Costalat
Journal:  AJNR Am J Neuroradiol       Date:  2019-03-14       Impact factor: 3.825

3.  Delayed rupture of intracranial aneurysms after placement of intra-luminal flow diverter.

Authors:  Kun Hou; Guichen Li; Xianli Lv; Baofeng Xu; Kan Xu; Jinlu Yu
Journal:  Neuroradiol J       Date:  2020-08-27

4.  Meta-Analysis of the Efficiency and Prognosis of Intracranial Aneurysm Treated with Flow Diverter Devices.

Authors:  Gengfan Ye; Meng Zhang; Lin Deng; Xiaohui Chen; Yunyan Wang
Journal:  J Mol Neurosci       Date:  2016-01-27       Impact factor: 3.444

5.  Endovascular Treatment of Large or Giant Basilar Artery Aneurysms Using the Pipeline Embolization Device: Complications and Outcomes.

Authors:  Huijian Ge; Xiheng Chen; Kai Liu; Yang Zhao; Longhui Zhang; Peng Liu; Yuhua Jiang; Hongwei He; Ming Lv; Youxiang Li
Journal:  Front Neurol       Date:  2022-03-02       Impact factor: 4.003

Review 6.  Flow diverter treatment of posterior circulation aneurysms. A meta-analysis.

Authors:  Cheng-Bin Wang; Wen-Wen Shi; Guang-Xu Zhang; Hu-Chen Lu; Jun Ma
Journal:  Neuroradiology       Date:  2016-01-22       Impact factor: 2.804

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.