Literature DB >> 23704358

Evaluation of image quality and radiation dose by adaptive statistical iterative reconstruction technique level for chest CT examination.

Sun Suk Hong1, Jong-Woong Lee, Jeong Beom Seo, Jae-Eun Jung, Jiwon Choi, Dae Cheol Kweon.   

Abstract

The purpose of this research is to determine the adaptive statistical iterative reconstruction (ASIR) level that enables optimal image quality and dose reduction in the chest computed tomography (CT) protocol with ASIR. A chest phantom with 0-50 % ASIR levels was scanned and then noise power spectrum (NPS), signal and noise and the degree of distortion of peak signal-to-noise ratio (PSNR) and the root-mean-square error (RMSE) were measured. In addition, the objectivity of the experiment was measured using the American College of Radiology (ACR) phantom. Moreover, on a qualitative basis, five lesions' resolution, latitude and distortion degree of chest phantom and their compiled statistics were evaluated. The NPS value decreased as the frequency increased. The lowest noise and deviation were at the 20 % ASIR level, mean 126.15 ± 22.21. As a result of the degree of distortion, signal-to-noise ratio and PSNR at 20 % ASIR level were at the highest value as 31.0 and 41.52. However, maximum absolute error and RMSE showed the lowest deviation value as 11.2 and 16. In the ACR phantom study, all ASIR levels were within acceptable allowance of guidelines. The 20 % ASIR level performed best in qualitative evaluation at five lesions of chest phantom as resolution score 4.3, latitude 3.47 and the degree of distortion 4.25. The 20 % ASIR level was proved to be the best in all experiments, noise, distortion evaluation using ImageJ and qualitative evaluation of five lesions of a chest phantom. Therefore, optimal images as well as reduce radiation dose would be acquired when 20 % ASIR level in thoracic CT is applied.

Entities:  

Mesh:

Year:  2013        PMID: 23704358     DOI: 10.1093/rpd/nct127

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  2 in total

1.  Full Dose-Reduction Potential of Statistical Iterative Reconstruction for Head CT Protocols in a Predominantly Pediatric Population.

Authors:  A E Mirro; S L Brady; R A Kaufman
Journal:  AJNR Am J Neuroradiol       Date:  2016-04-07       Impact factor: 3.825

2.  Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children.

Authors:  Haesung Yoon; Myung-Joon Kim; Choon-Sik Yoon; Jiin Choi; Hyun Joo Shin; Hyun Gi Kim; Mi-Jung Lee
Journal:  Pediatr Radiol       Date:  2014-09-26
  2 in total