Literature DB >> 23704080

Transcatheter trans-septal antegrade closure of muscular ventricular septal defects in young children.

Nageswara Rao Koneti1, Sudeep Verma, Shweta Bakhru, Karunakar Vadlamudi, Pallavi Kathare, Raghava Raju Penumatsa, Shakeel Qureshi.   

Abstract

BACKGROUND: Surgical or transcatheter closure of muscular ventricular septal defects (mVSDs) in young children may be technically challenging and associated with significant complications.
OBJECTIVE: To assess the feasibility of trans-septal antegrade closure of mVSD in a selected subset of young children.
METHODS: This is a prospective study from a single centre from July 2011 to March 2013. Nine infants and children with single or multiple mVSDs were included in the study. The median age and weight were 6 months (range 4-18 months) and 4.5 kg (range 3.8-6.2 kg), respectively. Trans-femoral trans-septal antegrade technique was used in eight children. One child was excluded from the study because of abnormally tortuous anatomy of both the femoral veins and subsequently underwent VSD device closure by the trans-jugular approach. The follow-up evaluation included chest X-ray, ECG, and echocardiogram at 1 month, 3 months, 6 months, and 1 year.
RESULTS: The defects were closed successfully in all eight patients using Amplatzer mVSD device in 5 and Amplatzer Duct Occluder II in 3. Moderate mitral regurgitation due to entrapment of the anterior mitral leaflet occurred in one patient with a posteriorly located mVSD, necessitating removal of the device, and surgical closure of the mVSD. The small additional residual mVSD in one other patient closed spontaneously during the follow-up.
CONCLUSIONS: Transcatheter trans-septal antegrade closure of mVSD in young children is technically feasible and merits further consideration. Symptomatic relief in multiple mVSD can be achieved after closing larger defects.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  congenital heart disease; left to right shunts; muscular ventricular septal defect; muscular ventricular septal occluder; transcatheter device closure

Mesh:

Year:  2013        PMID: 23704080     DOI: 10.1002/ccd.25020

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Interventional VSD-Closure with the Nit-Occlud® Lê VSD-Coil in 110 Patients: Early and Midterm Results of the EUREVECO-Registry.

Authors:  Nikolaus A Haas; Laura Kock; Harald Bertram; Regina Boekenkamp; Daniel De Wolf; Igor Ditkivskyy; Matthias W Freund; Marc Gewillig; Christoph M Happel; Ulrike Herberg; Edvard Karthasyan; Rainer Kozlik-Feldmann; Oliver Kretschmar; Yulia Kuzmenko; Ornella Milanesi; Goetz Mueller; Giacomo Pongiglione; Stephan Schubert; Gleb Tarusinov; Christoph Kampmann
Journal:  Pediatr Cardiol       Date:  2016-11-15       Impact factor: 1.655

Review 2.  Interventional Cardiology for Congenital Heart Disease.

Authors:  Damien Kenny
Journal:  Korean Circ J       Date:  2018-03-29       Impact factor: 3.243

  2 in total