Literature DB >> 23702610

Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma.

Nevbahar Tamcelik1, Ahmet Ozkok, Ahmet Murat Sarıcı, Eray Atalay, Huseyin Yetik, Kivanc Gungor.   

Abstract

PURPOSE: To present and compare the long-term results of Dr. Tamcelik's previously described technique of Tenon advancement and duplication with the conventional Ahmed glaucoma valve (AGV) implantation technique in patients with refractory glaucoma.
METHODS: This study was a multicenter, retrospective case series that included 303 eyes of 276 patients with refractory glaucoma who underwent glaucoma valve implantation surgery. The patients were divided into three groups according to the surgical technique applied and the outcomes compared. In group 1, 96 eyes of 86 patients underwent AGV implant surgery without patch graft; in group 2, 78 eyes of 72 patients underwent AGV implant surgery with donor scleral patch; in group 3, 129 eyes of 118 patients underwent Ahmed valve implant surgery with "combined short scleral tunnel with Tenon advancement and duplication technique". The endpoint assessed was tube exposure through the conjunctiva.
RESULTS: In group 1, conjunctival tube exposure was seen in 11 eyes (12.9 %) after a mean 9.2 ± 3.7 years of follow-up. In group 2, conjunctival tube exposure was seen in six eyes (2.2 %) after a mean 8.9 ± 3.3 years of follow-up. In group 3, there was no conjunctival exposure after a mean 7.8 ± 2.8 years of follow-up. The difference between the groups was statistically significant. (P = 0.0001, Chi-square test).
CONCLUSION: This novel surgical technique combining a short scleral tunnel with Tenon advancement and duplication was found to be effective and safe to prevent conjunctival tube exposure after AGV implantation surgery in patients with refractory glaucoma.

Entities:  

Mesh:

Year:  2013        PMID: 23702610     DOI: 10.1007/s10384-013-0249-5

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  23 in total

1.  Scleral tunnel for the implantation of glaucoma seton devices.

Authors:  A Ozdamar; C Aras; C Ustundag; N Tamcelik; S Ozkan
Journal:  Ophthalmic Surg Lasers       Date:  2001 Sep-Oct

2.  A comparison of viscogoniotomy with classical goniotomy in Turkish patients.

Authors:  Nevbahar Tamçelik; Abdullah Ozkiriş
Journal:  Jpn J Ophthalmol       Date:  2004 Jul-Aug       Impact factor: 2.447

3.  A novel surgical technique to prevent postoperative Ahmed valve tube exposure through conjunctiva: tenon advancement and duplication.

Authors:  Nevbahar Tamçelik; Ahmet M Sarici; Huseyin Yetik; Ahmet Ozkök; Abdullah Ozkiris
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2010 May-Jun

4.  A comparison of glaucoma drainage implant tube coverage.

Authors:  M Fran Smith; J William Doyle; John W Ticrney
Journal:  J Glaucoma       Date:  2002-04       Impact factor: 2.503

5.  Scleral patch grafts with Molteno setons.

Authors:  J Freedman
Journal:  Ophthalmic Surg       Date:  1987-07

6.  Fascia lata patch graft in glaucoma tube surgery.

Authors:  T M Tanji; D C Lundy; D S Minckler; D K Heuer; R Varma
Journal:  Ophthalmology       Date:  1996-08       Impact factor: 12.079

7.  Creutzfeldt-Jakob disease associated with cadaveric dura mater grafts -- Japan, January 1979-May 1996.

Authors: 
Journal:  MMWR Morb Mortal Wkly Rep       Date:  1997-11-14       Impact factor: 17.586

8.  Long-term survival of Molteno glaucoma drainage devices.

Authors:  R P Mills; A Reynolds; M J Emond; W E Barlow; M M Leen
Journal:  Ophthalmology       Date:  1996-02       Impact factor: 12.079

9.  Baerveldt-350 implant versus Ahmed valve for refractory glaucoma: a case-controlled comparison.

Authors:  Hasan M Syed; Simon K Law; Sok H Nam; Gang Li; Joseph Caprioli; Anne Coleman
Journal:  J Glaucoma       Date:  2004-02       Impact factor: 2.503

10.  Risk factors of implant exposure outside the conjunctiva after Ahmed glaucoma valve implantation.

Authors:  Yong Soo Byun; Na Young Lee; Chan Kee Park
Journal:  Jpn J Ophthalmol       Date:  2009-03-31       Impact factor: 2.447

View more
  8 in total

1.  "Double scleral tunnel in tandem" technique for glaucoma drainage tube implants.

Authors:  Dimitrios Brouzas; Maria Dettoraki; Konstantinos Andreanos; Nikolaos Nomikarios; Chryssanthi Koutsandrea; Marilita M Moschos
Journal:  Int Ophthalmol       Date:  2017-10-23       Impact factor: 2.031

2.  Outcomes of the Shunt Tube Exposure Prevention Study: A Randomized Clinical Trial.

Authors:  Hosam Sheha; Celso Tello; Lama A Al-Aswad; Mohamed S Sayed; Richard K Lee
Journal:  Ophthalmol Glaucoma       Date:  2019-08-16

3.  Risk factors for hypertensive phase after Ahmed glaucoma valve implantation.

Authors:  Onur Özalp; Serdar İlgüy; Eray Atalay; Tülay Şimşek; Nilgün Yıldırım
Journal:  Int Ophthalmol       Date:  2021-08-22       Impact factor: 2.031

4.  Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.

Authors:  Oriel Spierer; Michael Waisbourd; Yitzhak Golan; Hadas Newman; Rony Rachmiel
Journal:  BMC Ophthalmol       Date:  2016-02-27       Impact factor: 2.209

5.  A novel surgical technique for prevention of Ahmed glaucoma valve tube exposure: long scleral flap augmented with Tenon advancement and duplication.

Authors:  O M Gedar Totuk; K Kabadayi; A Colakoglu; N Ekizoglu; U Aykan
Journal:  BMC Ophthalmol       Date:  2018-08-31       Impact factor: 2.209

6.  Partial thickness cornea tissue from small incision lenticule extraction: A novel patch graft in glaucoma drainage implant surgery.

Authors:  Yuhong Wang; Xiaofeng Li; Weiyi Huang; Jinkun Liu; Yazhang Xu; Meizhu Chen; Qian Wang
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

7.  Comparison of Locally Sourced Pericardium and Other Conventional Patch Graft Materials in a Glaucoma Drainage Device Surgery.

Authors:  Shruti Aggarwal; Candice Kremer; Stephanie Engelhard; Sandra Johnson
Journal:  J Curr Glaucoma Pract       Date:  2021 Jan-Apr

8.  Donor Cornea Use in Scleral Surface Reconstruction

Authors:  Ayşe Burcu; Züleyha Yalnız-Akkaya; Evin Şingar Özdemir; Selma Özbek-Uzman
Journal:  Turk J Ophthalmol       Date:  2021-08-27
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.