Printed circuit board ion trap mass analyzer: its structure and performance.

Dan Jiang1, Gong-Yu Jiang, Xiao-Xu Li, Fu-Xing Xu, Liang Wang, Li Ding, Chuan-Fan Ding.   

Abstract

An ion trap (IT) mass analyzer can be simply built with low cost material-the printed circuit board (PCB). A printed circuit board ion trap (PCBIT) can perform ion trapping, mass analysis, and tandem mass spectrometry as a conventional ion trap mass analyzer. In a PCBIT, each PCB electrode was fabricated to specially designed patterns with several separate electric strips. The strips' electrodes were insulated from each other and applied with different voltages during the experiment. Therefore, the electric field distribution inside the ion trap region may be adjusted and optimized by simply adjusting the voltage on each strip. The performance of the PCBIT can also be optimized since the property of an ion trap is strongly dependent on the field distribution. The fabrication, operation, and performance of the PCBIT are described and characterized in this paper. A prototype PCBIT was built with two pairs of 64 mm × 12 mm PCB rectangular plates and one pair of 10 mm × 10 mm stainless steel square plates. A mass analysis with a resolving power of over 1500 and a mass range of around 3000 Th was observed. The mass-selected isolation and collision-induced dissociation (CID) of ions were also tested using the homemade PCBIT system. The adjustable electric field distribution, simple structure, and low cost of PCBIT make it certainly suitable for the further miniaturization of the portable mass spectrometer.

Entities:  

Year:  2013        PMID: 23701673     DOI: 10.1021/ac400864k

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Simulation of Unidirectional Ion Ejection in an Asymmetric Half-Round Rod Electrode Linear Ion Trap Mass Analyzer.

Authors:  HaiYan Wu; LiPeng Zhang; ZaiYue Zhang; Jie Qian; ShuGuang Zhang; YingJun Zhang; SaiJin Ge; XiaoXu Li
Journal:  J Am Soc Mass Spectrom       Date:  2018-07-11       Impact factor: 3.109

3.  Chemical Mass Shifts in a Digital Linear Ion Trap as Analytical Identity of o-, m-, and p-Xylene.

Authors:  Lulu Sun; Bing Xue; Zhengxu Huang; Ping Cheng; Li Ma; Li Ding; Zhen Zhou
Journal:  J Am Soc Mass Spectrom       Date:  2018-04-30       Impact factor: 3.109

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.