Literature DB >> 23698236

The impact of neutral-pH peritoneal dialysates with reduced glucose degradation products on clinical outcomes in peritoneal dialysis patients.

Yeoungjee Cho1, David W Johnson, Sunil V Badve, Jonathan C Craig, Giovanni F M Strippoli, Kathryn J Wiggins.   

Abstract

Neutral-pH peritoneal dialysates, with reduced glucose degradation products (GDPs), have been developed to reduce peritoneal membrane damage. Here our review evaluated the impact of these solutions on clinical outcomes using data from The Cochrane CENTRAL Registry, MEDLINE, Embase, and reference lists for randomized trials of biocompatible solutions. Summary estimates of effect were obtained using a random-effects model of 20 eligible trials encompassing 1383 patients. The quality of studies was generally poor, such that 13 studies had greater than a 20% loss to follow-up and only 3 trials reported adequate concealment of allocation. Use of neutral-pH dialysates with reduced GDPs resulted in larger urine volumes (7 trials; 520 patients; mean difference 126 ml/day, 95% CI 27-226), improved residual renal function after 12 months (6 trials; 360 patients; standardized mean difference 0.31, 95% confidence interval 0.10-0.52), and a trend to reduced inflow pain (1 trial; 58 patients; relative risk 0.51, 95% CI 0.24-1.08). However, there was no significant effect on body weight, hospitalization, peritoneal solute transport rate, peritoneal small-solute clearance, peritonitis, technique failure, patient survival, or adverse events. No significant harms were identified. Thus, based on generally poor quality trials, the use of neutral-pH peritoneal dialysates with reduced GDPs resulted in greater urine volumes and residual renal function after 12 months, but without other clinical benefits. Larger, better-quality studies are needed for accurate evaluation of the impact of these newer dialysates on patient-level hard outcomes.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23698236     DOI: 10.1038/ki.2013.190

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  27 in total

1.  Epidemiology, meta-analysis, and macro-economics.

Authors:  Martin Wilkie
Journal:  Perit Dial Int       Date:  2013 Nov-Dec       Impact factor: 1.756

Review 2.  Effect of Neutral-pH, Low-Glucose Degradation Product Peritoneal Dialysis Solutions on Residual Renal Function, Urine Volume, and Ultrafiltration: A Systematic Review and Meta-Analysis.

Authors:  Seychelle Yohanna; Ali M A Alkatheeri; Scott K Brimble; Brendan McCormick; Arthur Iansavitchous; Peter G Blake; Arsh K Jain
Journal:  Clin J Am Soc Nephrol       Date:  2015-06-05       Impact factor: 8.237

3.  Is It Beneficial to Convert to a Neutral-pH Bicarbonate/Lactate-Buffered PD Solution in Long-Term CAPD Patients? A Single-Center Prospective Study.

Authors:  Tae-Hyun Yoo; Mi Jung Lee; Hyung Jung Oh; Jung Tak Park; Seung Hyeok Han; Shin-Wook Kang; Dae Suk Han
Journal:  Perit Dial Int       Date:  2015 May-Jun       Impact factor: 1.756

Review 4.  Peritoneal dialysis-related infections recommendations: 2016 update. What is new?

Authors:  Vassilios Liakopoulos; Olga Nikitidou; Theofanis Kalathas; Stefanos Roumeliotis; Marios Salmas; Theodoros Eleftheriadis
Journal:  Int Urol Nephrol       Date:  2017-06-01       Impact factor: 2.370

5.  Hydration Status of Patients Dialyzed with Biocompatible Peritoneal Dialysis Fluids.

Authors:  Monika Lichodziejewska-Niemierko; Michał Chmielewski; Maria Dudziak; Alicja Ryta; Bolesław Rutkowski
Journal:  Perit Dial Int       Date:  2015-10-16       Impact factor: 1.756

Review 6.  Effect of biocompatible peritoneal dialysis solution on residual renal function: a systematic review of randomized controlled trials.

Authors:  Eun-Young Seo; Sook Hee An; Jang-Hee Cho; Hae Sun Suh; Sun-Hee Park; Hyesun Gwak; Yong-Lim Kim; Hunjoo Ha
Journal:  Perit Dial Int       Date:  2014-09-02       Impact factor: 1.756

7.  Is the Effect of Low-GDP Solutions on Residual Renal Function Mediated by Fluid State? An Enigmatic Question which Still Needs to be Solved.

Authors:  Jeroen P Kooman; Tom Cornelis; Frank M van der Sande; Karel M L Leunissen
Journal:  Perit Dial Int       Date:  2016 May-Jun       Impact factor: 1.756

8.  Longitudinal Trend in Lipid Profile of Incident Peritoneal Dialysis Patients is Not Influenced by the Use of Biocompatible Solutions.

Authors:  Yeoungjee Cho; Janine Büchel; Sonja Steppan; Jutta Passlick-Deetjen; Carmel M Hawley; Goce Dimeski; Margaret Clarke; David W Johnson
Journal:  Perit Dial Int       Date:  2015-10-01       Impact factor: 1.756

9.  Utility of Urinary Biomarkers in Predicting Loss of Residual Renal Function: The balANZ Trial.

Authors:  Yeoungjee Cho; David W Johnson; David A Vesey; Carmel M Hawley; Margaret Clarke; Nicholas Topley
Journal:  Perit Dial Int       Date:  2014-04-07       Impact factor: 1.756

10.  32 years' experience of peritoneal dialysis-related peritonitis in a university hospital.

Authors:  Sadie van Esch; Raymond T Krediet; Dirk G Struijk
Journal:  Perit Dial Int       Date:  2014-03-01       Impact factor: 1.756