| Literature DB >> 23697343 |
John C McCallum1, Karl K Limmer, Anthony Perricone, Dennis Bandyk, Nikhil Kansal.
Abstract
Thoracic aortic endografting has been successfully implemented to treat aneurysmal disease of the distal aortic arch and descending thoracic aorta. Although there are reports of ascending aortic endovascular interventions, the total endovascular repair of a ruptured ascending aorta secondary to a Type A dissection has not been described. We report the case of a 77-year-old patient who presented with a ruptured ascending aortic aneurysm secondary to degeneration of a Stanford type A aortic dissection. His surgical history was significant for orthotropic heart transplant 19 years prior. The dissection, aneurysm, and rupture occurred in the native aorta distal to the ascending aortic suture line. At presentation, he was hemodynamically unstable with a right hemothorax. We placed 3 Medtronic Talent Thoracic Stent Graft devices (Medtronic Inc, Minneapolis, MN) across the suture line in the ascending aorta, excluding the rupture. The patient survived and has been followed to 25 months.Entities:
Keywords: TEVAR; ascending aorta; endovascular repair; thoracic aorta rupture
Mesh:
Year: 2013 PMID: 23697343 DOI: 10.1177/1538574413486838
Source DB: PubMed Journal: Vasc Endovascular Surg ISSN: 1538-5744 Impact factor: 1.089