| Literature DB >> 23695358 |
J Filipecki1, A Kocela, P Korzekwa, R Miedzinski, K Filipecka, E Golis, W Korzekwa.
Abstract
A study has been conducted in order to determine presence of free volume gaps in the structure of structure of polymer hydrogel contact lenses made in phosphoryl choline technology and of the degree of defect of its structure. The study was made by means of positron annihilation lifetime spectroscopy. As a result of the conducted measurements, curves were obtained, which described numbers of counts of the acts of annihilation in the time function. The conducted studies revealed existence of three components τ(1), τ(2) and τ(3). The τ(3) component is attributed to the pick-off annihilation of o-Ps orthopositronium trapping by free volume gaps and provides information about geometrical parameters of the volumes. At the same time, the UV-vis-NIR spectrometry examination was conducted on the same samples in the spectral range 200-1,000 nm.Entities:
Mesh:
Substances:
Year: 2013 PMID: 23695358 PMCID: PMC3713257 DOI: 10.1007/s10856-013-4948-8
Source DB: PubMed Journal: J Mater Sci Mater Med ISSN: 0957-4530 Impact factor: 3.896
Fig. 1Contact lens with a visible reservoir of bacteria
Family Proclear contact lenses used in the study
| Sample | Brand | Oxygen permeability: DK/t | Water content (%) | Material Omafilcon A (%) |
|---|---|---|---|---|
| 1 | Proclear asphere | 28 | 60 | 40 |
| 2 | Proclear sphere | 42 | 62 | 38 |
| 3 | Proclear ep | 16 | 60 | 40 |
| 4 | Proclear multifocal toric D | 42 | 59 | 41 |
| 5 | Proclear multifocal toric N | 42 | 59 | 41 |
Fig. 2The spectrum of positron lifetime in a contact lens sample
Fig. 3UV–vis–NIR transmission spectra for the examined contact lenses
Mean positron lifetime values τ1, τ2, τ3 and their intensities
| Sample | τ1 (ns) | I1 (%) | τ2 (ns) | I2 (%) | τ3 (ns) | I3 (%) |
|---|---|---|---|---|---|---|
| 1 asphere | 0.207 ± 0.006 | 76.03 ± 1.56 | 0.580 ± 0.034 | 18.23 ± 1.60 | 1.800 ± 0.180 | 5.75 ± 0.35 |
| 2 sphere | 0.180 ± 0.006 | 63.06 ± 0.97 | 0.476 ± 0.010 | 31.12 ± 0.97 | 1.803 ± 0.024 | 5.80 ± 0.19 |
| 3 ep | 0.211 ± 0.007 | 68.05 ± 1.45 | 0.533 ± 0.022 | 24.90 ± 1.53 | 1.822 ± 0.028 | 7.07 ± 0.30 |
| 4 multifocal toric D | 0.230 ± 0.005 | 71.34 ± 1.34 | 0.517 ± 0.054 | 24.01 ± 1.43 | 1.853 ± 0.075 | 4.66 ± 0.17 |
| 5 multifocal toric N | 0.235 ± 0.005 | 76.17 ± 1.43 | 0.564 ± 0.089 | 20.07 ± 1.47 | 1.893 ± 0.066 | 3.79 ± 0.26 |
Mean positron lifetime values τ3, their intensity I3 and sizes of free volumes
| Sample | τ3 (ns) | I3 (%) | R (nm) | Vf (10−30 m3) | fv (a.u.) |
|---|---|---|---|---|---|
| 1 asphere | 1.800 | 5.75 | 0.265 | 77.92 | 448.04 |
| 2 sphere | 1.803 | 5.80 | 0.266 | 78.80 | 457.04 |
| 3 ep | 1.822 | 7.07 | 0.268 | 80.59 | 569.77 |
| 4 multifocal toric D | 1.853 | 4.66 | 0.271 | 83.33 | 388.32 |
| 5 multifocal toric N | 1.893 | 3.79 | 0.275 | 87.08 | 330.03 |
Fig. 4The average size of free volume Vf for samples of contact lenses: 1 proclear asphere, 2 proclear sphere, 3 proclear ep, 4 proclear multifocal toric D, 5 proclear multifocal toric N
Fig. 5The fractional of free volume fv/C for samples of contact lenses: 1 proclear asphere, 2 proclear sphere, 3 proclear ep; 4 proclear multifocal toric D, 5 proclear multifocal toric N
Calculated values of positron lifetime and positron capture of the examined samples of contact lenses
| Sample | Fitting parameters | Parameters of positron capture | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| τ1 (ns) | I1 (%) | τ2 (ns) | I2 (%) | τ3 (ns) | I3 (%) | τav (ns) | τb (ns) | κd (ns−1) | τ2−τb
| τ2/τb (ns) | |
| 1 | 0.207 | 76.03 | 0.580 | 18.23 | 1.800 | 5.75 | 0.279 | 0.236 | 0.603 | 0.344 | 2.458 |
| 2 | 0.180 | 63.06 | 0.476 | 31.12 | 1.803 | 5.80 | 0.278 | 0.226 | 1.146 | 0.250 | 2.106 |
| 3 | 0.211 | 68.05 | 0.533 | 24.90 | 1.822 | 7.07 | 0.297 | 0.252 | 0.766 | 0.281 | 2.115 |
| 4 | 0.230 | 71.34 | 0.517 | 24.01 | 1.853 | 4.66 | 0.302 | 0.267 | 0.610 | 0.250 | 1.936 |
| 5 | 0.235 | 76.17 | 0.564 | 20.07 | 1.893 | 3.79 | 0.304 | 0.268 | 0.515 | 0.296 | 2.104 |