Comparison of the NucliSENS EasyQ HIV-1 v2.0 with Abbott m2000rt RealTime HIV-1 assay for plasma RNA quantitation in different HIV-1 subtypes.

Perpétua Gomes1, Ana Patrícia Carvalho, Isabel Diogo, Fátima Gonçalves, Inês Costa, Joaquim Cabanas, Ricardo Jorge Camacho.   

Abstract

Quantitation of HIV-1 RNA levels in plasma has significant prognostic value since high viral load concentrations in plasma are associated with a faster disease progression. Viral load testing became one the most important tools for monitoring HIV patients. New real time methodologies to quantify HIV viral load had arisen in the last decade. HIV is a virus with a high genetic variability, with the potential to negatively affect the performance of the viral load assays. Consequently, any new assay should be challenged against, at least, the most prevalent HIV-1 genetic variants. In the present study, the new version of NucliSENS EasyQ(®) HIV-1 (Version 2.0) quantitative assay was compared with another ultra-sensitive test--Abbott RealTime HIV-1--using 175 plasma samples from patients infected with several HIV-1 subtypes and recombinant forms: subtype B (41, 23%), subtype C (19, 11%), subtype G (76, 44%), and CRF02_AG (39, 22%). Overall, there was agreement between the assays in 95.43% of the samples. Both assays have a very good dynamic range [1.4-6.9] and [1.60-7.0] log10 copies/mL and excellent correlation in samples with various subtypes. Based on the fact that no clinically significant differences were observed in the viral load measurements by these two assays, HIV-1 subtypes are quantified equally by both assays. However due to HIV diversity, mainly in regions were non B subtypes are predominant more evaluations are needed, so we do not recommend to switch platform during longitudinal viral load monitoring.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  EasyQ HIV-1; HIV-1; Subtypes; m2000

Mesh:

Substances:

Year:  2013        PMID: 23692686     DOI: 10.1016/j.jviromet.2013.05.001

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  3 in total

1.  Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load.

Authors:  Orna Mor; Yael Gozlan; Marina Wax; Fernando Mileguir; Avia Rakovsky; Bina Noy; Ella Mendelson; Itzchak Levy
Journal:  J Clin Microbiol       Date:  2015-08-19       Impact factor: 5.948

Review 2.  Malaria Diagnosis Across the International Centers of Excellence for Malaria Research: Platforms, Performance, and Standardization.

Authors:  Tamaki Kobayashi; Dionicia Gamboa; Daouda Ndiaye; Liwang Cui; Patrick L Sutton; Joseph M Vinetz
Journal:  Am J Trop Med Hyg       Date:  2015-08-10       Impact factor: 2.345

3.  Evaluation of the NucliSens EasyQ v2.0 assay in comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in quantification of C-clade HIV-1 in plasma.

Authors:  Maximilian Muenchhoff; Savathee Madurai; Allison Jo Hempenstall; Emily Adland; Anna Carlqvist; Angeline Moonsamy; Manjeetha Jaggernath; Busisiwe Mlotshwa; Emma Siboto; Thumbi Ndung'u; Philip Jeremy Renshaw Goulder
Journal:  PLoS One       Date:  2014-08-26       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.