Literature DB >> 23688682

Effect of mobile phase additives on qualitative and quantitative analysis of ginsenosides by liquid chromatography hybrid quadrupole-time of flight mass spectrometry.

Yan Liang1, Tianye Guan, Yuanyuan Zhou, Yanna Liu, Lu Xing, Xiao Zheng, Chen Dai, Ping Du, Tai Rao, Lijun Zhou, Xiaoyi Yu, Kun Hao, Lin Xie, Guangji Wang.   

Abstract

This study was to systematically investigate the effect of mobile phase additives, including ammonia water, formic acid, acetic acid, ammonium chloride and water (as a control), on qualitative and quantitative analysis of fifteen representative ginsenosides based on liquid chromatography hybrid quadrupole-time of flight mass spectrometry (LC-Q-TOF/MS). To evaluate the influence of mobile phase additives on qualitative performance, the quality of the negative mode MS/MS spectra of ginsenosides produced by online LC-Q-TOF/MS analyses, particularly the numbers and intensities of fragment ions, were compared under different adduct ion states, and found to be strongly affected by the mobile phase additives. When 0.02% acetic acid was added in the mobile phase, the deprotonated ginsenosides ions produced the most abundant product ions, while almost no product ion was observed for the chlorinated ginsenoside ions when 0.1mM ammonium chloride was used as the mobile phase additive. On the other hand, sensitivity, linear range and precision were adopted to investigate the quantitative performance affected by different mobile phase additives. Validation results of the LC-Q-TOF/MS-based quantitative performance for ginsenosides showed that ammonium chloride not only provided the highest sensitivity for all the target analytes, but also dramatically improved the linear ranges, the intra-day and inter-day precisions comparing to the results obtained using other mobile phase additives. Importantly, the validated method, using 0.1mM ammonium chloride as the mobile phase additive, was successfully applied to the quantitative analysis of ginsenosides in rat plasma after intragastric administration of Ginsenoside Extract at 200mg/kg. In conclusion, 0.02% acetic acid was deemed to be the most suitable mobile phase additive for qualitative analysis of ginsenosides, and 0.1mM ammonium chloride in mobile phase could lead to the best quantitative performance. Our results reveal that choosing the appropriate mobile phase additive is an important step in optimizing the analytical conditions, and the best quantitative method may not be suitable for the qualitative analysis.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23688682     DOI: 10.1016/j.chroma.2013.04.001

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Eco-Friendly, Simple, Fast, and Sensitive UPLC-MS/MS Method for Determination of Pexidartinib in Plasma and Its Application to Metabolic Stability.

Authors:  Essam Ezzeldin; Muzaffar Iqbal; Yousif A Asiri; Gamal A E Mostafa; Ahmed Y A Sayed
Journal:  Molecules       Date:  2022-01-04       Impact factor: 4.411

2.  Quantitative Analysis of Panax ginseng by FT-NIR Spectroscopy.

Authors:  Xin-Fang Xu; Li-Xing Nie; Li-Li Pan; Bian Hao; Shao-Xiong Yuan; Rui-Chao Lin; Hai-Bo Bu; Dan Wang; Ling Dong; Xiang-Ri Li
Journal:  J Anal Methods Chem       Date:  2014-05-05       Impact factor: 2.193

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.