PURPOSE: Revision of a shoulder arthroplasty to a reverse arthroplasty is a highly demanding procedure. The aim of this study is to report the clinical results of hemi and total shoulder prosthesis revisions to reverse implants without removal of the humeral stem, using a modular shoulder replacement system (SMR Lima LTD). We retrospectively reviewed 26 patients who underwent an operation from 2004 to 2009. METHODS: The patients were divided into two groups: in Group I, 18 patients underwent a revision of hemiarthroplasty implanted for fracture; in Group II, eight patients underwent a revision of anatomical total prosthesis. All patients were evaluated at a mean follow-up of 32.3 (±12.7) months using the Constant score rating scale and by range of motion evaluation, EQ-VAS, X-ray and CT scan. RESULTS: The Constant score of each patient was 47.88 (±5.88) after the revision. The EQ-VAS improved from 40 (±20) to 70 (±10). All patients improved in terms of range of motion. The radiographs and CT scans obtained after revision showed good integration and no signs of loosening of the implant. The mean time of surgery was recorded as 62' (±8'), with a maximum blood loss of less than 300 ml in all cases. CONCLUSIONS: Our study demonstrates that using a full modular system at the time of the first implant allows avoidance of the step to remove the humeral stem and metal back in cases of shoulder prosthesis revision to a reverse prosthesis, resulting in a short operative time, few intraoperative complications and a satisfactory clinical outcome at medium-term follow-up.
PURPOSE: Revision of a shoulder arthroplasty to a reverse arthroplasty is a highly demanding procedure. The aim of this study is to report the clinical results of hemi and total shoulder prosthesis revisions to reverse implants without removal of the humeral stem, using a modular shoulder replacement system (SMR Lima LTD). We retrospectively reviewed 26 patients who underwent an operation from 2004 to 2009. METHODS: The patients were divided into two groups: in Group I, 18 patients underwent a revision of hemiarthroplasty implanted for fracture; in Group II, eight patients underwent a revision of anatomical total prosthesis. All patients were evaluated at a mean follow-up of 32.3 (±12.7) months using the Constant score rating scale and by range of motion evaluation, EQ-VAS, X-ray and CT scan. RESULTS: The Constant score of each patient was 47.88 (±5.88) after the revision. The EQ-VAS improved from 40 (±20) to 70 (±10). All patients improved in terms of range of motion. The radiographs and CT scans obtained after revision showed good integration and no signs of loosening of the implant. The mean time of surgery was recorded as 62' (±8'), with a maximum blood loss of less than 300 ml in all cases. CONCLUSIONS: Our study demonstrates that using a full modular system at the time of the first implant allows avoidance of the step to remove the humeral stem and metal back in cases of shoulder prosthesis revision to a reverse prosthesis, resulting in a short operative time, few intraoperative complications and a satisfactory clinical outcome at medium-term follow-up.
Authors: John W Sperling; Samuel A Antuna; Joaquin Sanchez-Sotelo; Cathy Schleck; Robert H Cofield Journal: J Bone Joint Surg Am Date: 2002-10 Impact factor: 5.284
Authors: Michael John; Géza Pap; Felix Angst; Matthias P Flury; Sebastian Lieske; Hans-Kaspar Schwyzer; Beat Rene Simmen Journal: Int Orthop Date: 2009-02-17 Impact factor: 3.075
Authors: Bryan Wall; Laurent Nové-Josserand; Daniel P O'Connor; T Bradley Edwards; Gilles Walch Journal: J Bone Joint Surg Am Date: 2007-07 Impact factor: 5.284
Authors: Petra Magosch; Sven Lichtenberg; Mark Tauber; Frank Martetschläger; Peter Habermeyer Journal: Arch Orthop Trauma Surg Date: 2020-04-23 Impact factor: 3.067
Authors: Adam Seidl; Daniel Sholder; William Warrender; Michael Livesey; Gerald Williams; Joseph Abboud; Surena Namdari Journal: Arch Bone Jt Surg Date: 2017-07
Authors: Albert Ferrando; Luis Natera; Berta Buch; Paolo Consigliere; Juan Bruguera; Giuseppe Sforza; Ehud Atoun; Ofer Levy Journal: Eur J Orthop Surg Traumatol Date: 2020-10-22