Literature DB >> 23684553

Quantification of dry needling and posture effects on myofascial trigger points using ultrasound shear-wave elastography.

Ruth M Maher1, Dawn M Hayes, Minoru Shinohara.   

Abstract

OBJECTIVES: To determine (1) whether the shear modulus in upper trapezius muscle myofascial trigger points (MTrPs) reduces acutely after dry needling (DN), and (2) whether a change in posture from sitting to prone affects the shear modulus.
DESIGN: Ultrasound images were acquired in B mode with a linear transducer oriented in the transverse plane, followed by performance of shear-wave elastography (SWE) before and after DN and while sitting and prone.
SETTING: University. PARTICIPANTS: Women (N=7; mean age ± SD, 46±17y) with palpable MTrPs were recruited. INTERVENTION: All participants were dry needled in the prone position using solid filament needles that were inserted and manipulated inside the MTrPs. SWE was performed before and after DN in the sitting and prone positions. MAIN OUTCOME MEASURE: MTrPs were evaluated by shear modulus using SWE.
RESULTS: Palpable reductions in stiffness were noted after DN and in the prone position. These changes were apparent in the shear modulus map obtained with ultrasound SWE. With significant main effects, the shear modulus reduced from before to after DN (P<.01) and from the sitting to the prone position (P<.05). No significant interaction effect between time and posture was observed.
CONCLUSIONS: The shear modulus measured with ultrasound SWE reduced after DN and in the prone position compared with sitting, in agreement with reductions in palpable stiffness. These findings suggest that DN and posture have significant effects on the shear modulus of MTrPs, and that shear modulus measurement with ultrasound SWE may be sensitive enough to detect these effects.
Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ANOVA; Elasticity imaging techniques; LTR; MTrPs; Rehabilitation; Trigger points; Ultrasonography; analysis of variance; local twitch response; myofascial trigger points

Mesh:

Year:  2013        PMID: 23684553     DOI: 10.1016/j.apmr.2013.04.021

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  14 in total

1.  Dry needling for the management of thoracic spine pain.

Authors:  César Fernández-de-Las-Peñas; Michelle Layton; Jan Dommerholt
Journal:  J Man Manip Ther       Date:  2015-07

2.  Shear-wave sonoelastography for assessing masseter muscle hardness in comparison with strain sonoelastography: study with phantoms and healthy volunteers.

Authors:  Yoshiko Ariji; Miwa Nakayama; Wataru Nishiyama; Michihito Nozawa; Eiichiro Ariji
Journal:  Dentomaxillofac Radiol       Date:  2015-12-01       Impact factor: 2.419

3.  A narrative review of new trends in the diagnosis of myofascial trigger points: diagnostic ultrasound imaging and biomarkers.

Authors:  John Z Srbely; Dinesh Kumbhare; Liza Grosman-Rimon
Journal:  J Can Chiropr Assoc       Date:  2016-09

4.  Effect of dry needling on lumbar muscle stiffness in patients with low back pain: A double blind, randomized controlled trial using shear wave elastography.

Authors:  Shane L Koppenhaver; Amelia M Weaver; Tyler L Randall; Ryan J Hollins; Brian A Young; Jeffrey J Hebert; Laurel Proulx; Cesar Fernández-de-Las-Peñas
Journal:  J Man Manip Ther       Date:  2021-09-16

5.  Assessment of Myofascial Trigger Points via Imaging: A Systematic Review.

Authors:  Dario F Mazza; Robert D Boutin; Abhijit J Chaudhari
Journal:  Am J Phys Med Rehabil       Date:  2021-10-01       Impact factor: 3.412

Review 6.  Assessment of the mechanical properties of the muscle-tendon unit by supersonic shear wave imaging elastography: a review.

Authors:  Kelly Mônica Marinho E Lima; José Francisco Silva Costa Júnior; Wagner Coelho de Albuquerque Pereira; Liliam Fernandes de Oliveira
Journal:  Ultrasonography       Date:  2017-04-15

7.  Scanning electron microscopy examination of needle tips after different procedures of deep dry needling in humans.

Authors:  Emilio J Poveda-Pagán; Sergio Hernández-Sánchez; Luis Rhys-Jones-López; Antonio Palazón-Bru; Carlos Lozano-Quijada
Journal:  Sci Rep       Date:  2018-12-19       Impact factor: 4.379

8.  Changes in Muscle Stiffness of the Trapezius Muscle After Application of Ischemic Compression into Myofascial Trigger Points in Professional Basketball Players.

Authors:  Aleksandra Kisilewicz; Marcin Janusiak; Rafał Szafraniec; Małgorzata Smoter; Bogdan Ciszek; Pascal Madeleine; César Fernández-de-Las-Peñas; Adam Kawczyński
Journal:  J Hum Kinet       Date:  2018-10-15       Impact factor: 2.193

9.  Modulation in Elastic Properties of Upper Trapezius with Varying Neck Angle.

Authors:  Jun Zhang; Jiafeng Yu; Chunlong Liu; Chunzhi Tang; Zhijie Zhang
Journal:  Appl Bionics Biomech       Date:  2019-03-03       Impact factor: 1.781

10.  Reliability of the Upper Trapezius Muscle and Fascia Thickness and Strain Ratio Measures by Ultrasonography and Sonoelastography in Participants With Myofascial Pain Syndrome.

Authors:  Mahyar Salavati; Behnam Akhbari; Ismail Ebrahimi Takamjani; Kamran Ezzati; Hamidreza Haghighatkhah
Journal:  J Chiropr Med       Date:  2017-10-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.