Literature DB >> 23684283

Two-body wear rate of CAD/CAM resin blocks and their enamel antagonists.

Bogna Stawarczyk1, Mutlu Özcan, Albert Trottmann, Felix Schmutz, Malgorzata Roos, Christoph Hämmerle.   

Abstract

STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD/CAM) resins exhibit good mechanical properties and can be used as long-term restorations. The wear rate of such resins and their enamel antagonists is unknown.
PURPOSE: The purpose of this study was to test and compare the 2-body wear rate of CAD/CAM resin blocks.
MATERIAL AND METHODS: Wear specimens (N=42, n=6) were made from 5 CAD/CAM resins: ZENO PMMA (ZP), artBloc Temp (AT), Telio CAD (TC), Blanc High-class (HC), CAD-Temp (CT); 1 manually polymerized resin: Integral esthetic press (negative control group, IEP); and 1 glass-ceramic: VITA Mark II (positive control group, VM2). The specimens for the wear resistance were aged in a thermomechanical loading machine (49 N, 1.67 Hz, 5/50°C) with human enamel antagonists. The material loss of all specimens before, during, and after aging was evaluated with a 3DS profilometer. The measured material loss data of all tested groups were statistically evaluated with linear mixed model analysis (a=.05).
RESULTS: Manually polymerized resin showed significantly higher material wear (P<.001) than all other tested groups. Glass-ceramic showed significantly lower wear values (P<.001) than CAD/CAM resins ZP, AT, HC, CT, and IES. CAD/CAM resin TC was not significantly different from the positive control group. Glass-ceramic showed the highest enamel wear values (P<.001) of all tested resins. No differences were found in the enamel wear among all resins. The glass-ceramic group showed damage in the form of cracks on the worn enamel surface in 50% of specimens.
CONCLUSIONS: CAD/CAM resins showed lower wear rates than those conventionally polymerized. Only one CAD/CAM resin, TC, presented material wear values comparable with glass-ceramic. The tested glass-ceramic developed cracks in the enamel antagonist and showed the highest enamel wear values of all other tested groups.
Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23684283     DOI: 10.1016/S0022-3913(13)60309-1

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  20 in total

1.  Bonding between CAD/CAM resin and resin composite cements dependent on bonding agents: three different in vitro test methods.

Authors:  Simona Gilbert; Christine Keul; Malgorzata Roos; Daniel Edelhoff; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2015-05-24       Impact factor: 3.573

2.  In-vitro performance of CAD/CAM-fabricated implant-supported temporary crowns.

Authors:  Martin Rosentritt; Philipp Raab; Sebastian Hahnel; Matthias Stöckle; Verena Preis
Journal:  Clin Oral Investig       Date:  2017-01-21       Impact factor: 3.573

3.  Influence of cleaning methods after 3D printing on two-body wear and fracture load of resin-based temporary crown and bridge material.

Authors:  Johannes Mayer; Bogna Stawarczyk; Konstantin Vogt; Reinhard Hickel; Daniel Edelhoff; Marcel Reymus
Journal:  Clin Oral Investig       Date:  2021-04-03       Impact factor: 3.573

4.  Effectiveness of surface treatment on bond strength of ceramic brackets to two types of CAD/CAM-prepared nanohybrid composites.

Authors:  Shaymaa Elsaka; Ali Hassan; Amr Elnaghy
Journal:  J Orofac Orthop       Date:  2022-02-21       Impact factor: 1.938

5.  The effect of different pretreatment methods of PMMA-based crowns on the long-term tensile bond strength to dentin abutments.

Authors:  Christine Keul; Daliah Kohen; Marlis Eichberger; Malgorzata Roos; Wolfgang Gernet; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2014-03-02       Impact factor: 3.573

6.  Tensile bond strength of resin composite repair in vitro using different surface preparation conditionings to an aged CAD/CAM resin nanoceramic.

Authors:  Bogna Stawarczyk; Andreas Krawczuk; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2014-06-15       Impact factor: 3.573

7.  Effect of thickness on color appearance of multilayer CAD/CAM composite resin blocks.

Authors:  Roubing Ha; Yumi Tsuchida; Maho Shiozawa; Hidekazu Takahashi
Journal:  Odontology       Date:  2022-03-24       Impact factor: 2.885

8.  Microtensile bond strength and micromorphologic analysis of surface-treated resin nanoceramics.

Authors:  Joon-Ho Park; Yu-Sung Choi
Journal:  J Adv Prosthodont       Date:  2016-08-18       Impact factor: 1.904

9.  In Vitro Investigation of Wear of CAD/CAM Polymeric Materials Against Primary Teeth.

Authors:  Jae-Won Choi; Eun-Ju Song; Jong-Hyun Shin; Tae-Sung Jeong; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2017-12-09       Impact factor: 3.623

10.  In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years.

Authors:  Gintare Burian; Kurt Erdelt; Josef Schweiger; Christine Keul; Daniel Edelhoff; Jan-Frederik Güth
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.