Literature DB >> 23683972

Accuracy of three-dimensional versus two-dimensional echocardiography for quantification of aortic regurgitation and validation by three-dimensional three-directional velocity-encoded magnetic resonance imaging.

See Hooi Ewe1, Victoria Delgado, Rob van der Geest, Jos J M Westenberg, Marlieke L A Haeck, Tomasz G Witkowski, Dominique Auger, Nina Ajmone Marsan, Eduard R Holman, Albert de Roos, Martin J Schalij, Jeroen J Bax, Allard Sieders, Hans-Marc J Siebelink.   

Abstract

Quantitative assessment of aortic regurgitation (AR) remains challenging. The present study evaluated the accuracy of 2-dimensional (2D) and 3-dimensional (3D) transthoracic echocardiography (TTE) for AR quantification, using 3D 3-directional velocity-encoded magnetic resonance imaging (VE-MRI) as the reference method. Thirty-two AR patients were included. With color Doppler TTE, 2D effective regurgitant orifice area (EROA) was calculated using the proximal isovelocity surface area method. From the 3D TTE multiplanar reformation data, 3D-EROA was calculated by planimetry of the vena contracta. Regurgitant volumes (RVol) were obtained by multiplying the 2D-EROA and 3D-EROA by the velocity-time integral of AR jet and compared with that obtained using VE-MRI. For the entire population, 3D TTE RVol demonstrated a strong correlation and good agreement with VE-MRI RVol (r = 0.94 and -13.6 to 15.6 ml/beat, respectively), whereas 2D TTE RVol showed a modest correlation and large limits of agreement with VE-MRI (r = 0.70 and -22.2 to 32.8 ml/beat, respectively). Eccentric jets were noted in 16 patients (50%). In these patients, 3D TTE demonstrated an excellent correlation (r = 0.95) with VE-MRI, a small bias (0.1 ml/beat) and narrow limits of agreement (-18.7 to 18.8 ml/beat). Finally, the kappa agreement between 3D TTE and VE-MRI for grading of AR severity was good (k = 0.96), whereas the kappa agreement between 2D TTE and VE-MRI was suboptimal (k = 0.53). In conclusion, AR RVol quantification using 3D TTE is accurate, and its advantage over 2D TTE is particularly evident in patients with eccentric jets.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23683972     DOI: 10.1016/j.amjcard.2013.04.025

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  17 in total

1.  Automatic quantification of aortic regurgitation using 3D full volume color doppler echocardiography: a validation study with cardiac magnetic resonance imaging.

Authors:  Jaehuk Choi; Geu-Ru Hong; Minji Kim; In Jeong Cho; Chi Young Shim; Hyuk-Jae Chang; Joel Mancina; Jong-Won Ha; Namsik Chung
Journal:  Int J Cardiovasc Imaging       Date:  2015-07-12       Impact factor: 2.357

Review 2.  [Application fields of intraoperative transesophageal 3D echocardiography].

Authors:  H Magunia; P Rosenberger
Journal:  Anaesthesist       Date:  2014-09       Impact factor: 1.041

Review 3.  Role of Echocardiography in the Evaluation of Left Ventricular Assist Devices: the Importance of Emerging Technologies.

Authors:  Luca Longobardo; Christopher Kramer; Scipione Carerj; Concetta Zito; Renuka Jain; Valentin Suma; Vinay Thohan; Nasir Sulemanjee; Frank X Downey; Bijoy K Khandheria
Journal:  Curr Cardiol Rep       Date:  2016-07       Impact factor: 2.931

Review 4.  [Real-time 3D echocardiography for estimation of severity in valvular heart disease : Impact on current guidelines].

Authors:  T Buck; L Bösche; B Plicht
Journal:  Herz       Date:  2017-05       Impact factor: 1.443

Review 5.  Advanced imaging in valvular heart disease.

Authors:  Jeroen J Bax; Victoria Delgado
Journal:  Nat Rev Cardiol       Date:  2017-01-27       Impact factor: 32.419

6.  Aortic and mitral flow quantification using dynamic valve tracking and machine learning: Prospective study assessing static and dynamic plane repeatability, variability and agreement.

Authors:  Julio Garcia; Kailey Beckie; Ali F Hassanabad; Alireza Sojoudi; James A White
Journal:  JRSM Cardiovasc Dis       Date:  2021-02-27

Review 7.  Role of modern 3D echocardiography in valvular heart disease.

Authors:  Takahiro Shiota
Journal:  Korean J Intern Med       Date:  2014-10-31       Impact factor: 2.884

8.  Evaluation of left atrial volume and function using single-beat real-time three-dimensional echocardiography in atrial fibrillation patients.

Authors:  Qian Zhang; Ju-Fang Wang; Qing-Qing Dong; Qing Yan; Xiang-Hong Luo; Xue-Ying Wu; Jian Liu; Ya-Ping Sun
Journal:  BMC Med Imaging       Date:  2017-07-21       Impact factor: 1.930

9.  Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI.

Authors:  Stephan Stoebe; Michael Metze; Daniel Jurisch; Bhupendar Tayal; Kilian Solty; Ulrich Laufs; Dietrich Pfeiffer; Andreas Hagendorff
Journal:  Echo Res Pract       Date:  2018-06-01

Review 10.  Clinical applications of intra-cardiac four-dimensional flow cardiovascular magnetic resonance: A systematic review.

Authors:  Saul Crandon; Mohammed S M Elbaz; Jos J M Westenberg; Rob J van der Geest; Sven Plein; Pankaj Garg
Journal:  Int J Cardiol       Date:  2017-09-28       Impact factor: 4.164

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.