Literature DB >> 23683519

Total knee arthroplasty with an uncemented trabecular metal tibial component: a registry-based analysis.

Mika Niemeläinen1, Eerik T Skyttä, Ville Remes, Keijo Mäkelä, Antti Eskelinen.   

Abstract

Previous poor results have kept the appeal of uncemented total knee arthroplasties (TKAs) minimal. We analyzed the mid-term survivorship and reasons for failures of a contemporary uncemented porous tantalum monoblock tibial component nation-wide. During the study period (2003-2010), such tibial components were used in 1143 primary TKAs recorded in the Finnish Arthroplasty Registry. Seven-year survivorship of these TKAs was 100% (95% CI 99-100) with revision for aseptic loosening of the tibial component, and 97% (95% CI 96-98) with revision for any reason as the respective end points. The most common reasons for revisions were instability and prosthetic joint infections. In conclusion, TKAs using an uncemented porous tantalum monoblock tibial component showed excellent mid-term survivorship in a population-based setting.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  porous tantalum tibial component; total knee arthroplasty; trabecular metal; uncemented

Mesh:

Substances:

Year:  2013        PMID: 23683519     DOI: 10.1016/j.arth.2013.04.014

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

1.  The Mark Coventry Award: Trabecular metal tibial components were durable and reliable in primary total knee arthroplasty: a randomized clinical trial.

Authors:  Luis Pulido; Matthew P Abdel; David G Lewallen; Michael J Stuart; Joaquin Sanchez-Sotelo; Arlen D Hanssen; Mark W Pagnano
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

2.  Is There A Difference in Bone Ingrowth in Modular Versus Monoblock Porous Tantalum Tibial Trays?

Authors:  Josa A Hanzlik; Judd S Day; Clare M Rimnac; Steven M Kurtz
Journal:  J Arthroplasty       Date:  2015-01-22       Impact factor: 4.757

3.  Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis.

Authors:  Kai Ding; Weijie Yang; Jian Zhu; Xiaodong Cheng; Haicheng Wang; Du Hao; Song Yinuo; Yanbin Zhu; Yingze Zhang; Wei Chen; Qi Zhang
Journal:  J Orthop Surg Res       Date:  2021-08-18       Impact factor: 2.359

4.  Use of porous monoblock patella component should avoid for patient with patella baja.

Authors:  Takao Kaneko; Norihiko Kono; Yuta Mochizuki; Hiroyasu Ikegami; Yoshiro Musha
Journal:  J Orthop       Date:  2018-03-23

5.  Trabecular metal tibial knee component still stable at 10 years.

Authors:  Anders Henricson; Kjell G Nilsson
Journal:  Acta Orthop       Date:  2016-06-30       Impact factor: 3.717

6.  Long-term results of a porous tantalum monoblock tibia component: clinical and radiographic results at follow-up of 10 years.

Authors:  Daniel Gerscovich; Catherine Schwing; Anthony Unger
Journal:  Arthroplast Today       Date:  2017-04-07

7.  The effect of fixation type on the survivorship of contemporary total knee arthroplasty in patients younger than 65 years of age: a register-based study of 115,177 knees in the Nordic Arthroplasty Register Association (NARA) 2000-2016.

Authors:  Mika J Niemeläinen; Keijo T Mäkelä; Otto Robertsson; Annette W-Dahl; Ove Furnes; Anne M Fenstad; Alma B Pedersen; Henrik M Schrøder; Aleksi Reito; Antti Eskelinen
Journal:  Acta Orthop       Date:  2020-01-13       Impact factor: 3.717

8.  Total Knee Replacement with an Uncemented Porous Tantalum Tibia Component: A Failure Analysis.

Authors:  Samo K Fokter; Nenad Gubeljak; Esther Punzón-Quijorna; Primož Pelicon; Mitja Kelemen; Primož Vavpetič; Jožef Predan; Luka Ferlič; Igor Novak
Journal:  Materials (Basel)       Date:  2022-03-31       Impact factor: 3.623

9.  Radiolucent lines are decreased at 3 years following total knee arthroplasty using trabecular metal tibial components.

Authors:  Hirotaka Mutsuzaki; Arata Watanabe; Tomonori Kinugasa; Kotaro Ikeda
Journal:  J Int Med Res       Date:  2018-03-20       Impact factor: 1.671

10.  Catastrophic tibial baseplate failure of a modern cementless total knee arthroplasty implant.

Authors:  William F Scully; Matthew E Deren; Michael R Bloomfield
Journal:  Arthroplast Today       Date:  2019-10-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.