Literature DB >> 23680302

An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system.

Ki-Baek Kim1, Woong-Chul Kim, Hae-Young Kim, Ji-Hwan Kim.   

Abstract

OBJECTIVES: This in vitro study aimed to evaluate and compare marginal fit of three-unit fixed dental prostheses (FDPs) fabricated using a newly developed direct metal laser sintering (DMLS) system with that of three-unit FDPs by a conventional lost wax technique (LW) method.
METHODS: Ten cobalt-chromium alloy three-unit FDPs using DMLS system and another ten nickel-chromium alloy FDPs using LW method were fabricated. Marginal fit was examined using a light-body silicone. After setting, the silicon film was cut into four parts and the thickness of silicon layer was measured at 160× magnification using a digital microscope to measure absolute marginal discrepancy (AMD), marginal gap (MG) and internal gap (IG). A repeated measure ANOVA for statistical analysis was performed using the SPSS statistical package version 12.0 (α=0.05).
RESULTS: The mean values of AMD, MG, and IG were significantly larger in the DMLS group than in the LW group (p<0.001). Means of AMD, MG and IG in the first molars were 83.3, 80.0, and 82.0μm in the LW group; and 128.0, 112.0, and 159.5μm in the DMLS group, respectively. No significant difference between measurements for premolars and molars was found (p>0.05). SIGNIFICANCE: The marginal fit of the DMLS system appeared significantly inferior compared to that of the conventional LW method and slightly larger than the acceptable range. For clinical application further improvement of DMLS system may be required.
Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23680302     DOI: 10.1016/j.dental.2013.04.007

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  18 in total

1.  Additive manufacturing of biomaterials.

Authors:  Susmita Bose; Dongxu Ke; Himanshu Sahasrabudhe; Amit Bandyopadhyay
Journal:  Prog Mater Sci       Date:  2017-08-26

2.  Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars.

Authors:  Ali Alenezi; Mohammed Yehya; Mohamed Alkhodary
Journal:  Saudi Dent J       Date:  2022-08-28

3.  Evaluation of marginal and internal gaps in single and three-unit metal frameworks made by micro-stereolithography.

Authors:  Dong-Yeon Kim; Ha-Na Lee; Ji-Hwan Kim; Hae-Young Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

4.  A Comparative Analysis of the Corrosive Effect of Artificial Saliva of Variable pH on DMLS and Cast Co-Cr-Mo Dental Alloy.

Authors:  Tatjana Puskar; Danimir Jevremovic; Robert J Williams; Dominic Eggbeer; Djordje Vukelic; Igor Budak
Journal:  Materials (Basel)       Date:  2014-09-11       Impact factor: 3.623

5.  Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography.

Authors:  Dong-Yeon Kim; Chong-Myeong Kim; Ji-Hwan Kim; Hae-Young Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

6.  An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks.

Authors:  Jae-Kwan Jung
Journal:  Biomed Res Int       Date:  2017-01-29       Impact factor: 3.411

7.  Marginal Accuracy and Internal Fit of 3-D Printing Laser-Sintered Co-Cr Alloy Copings.

Authors:  Myung-Joo Kim; Yun-Jung Choi; Seong-Kyun Kim; Seong-Joo Heo; Jai-Young Koak
Journal:  Materials (Basel)       Date:  2017-01-23       Impact factor: 3.623

8.  Comparison of prosthetic models produced by traditional and additive manufacturing methods.

Authors:  Jin-Young Park; Hae-Young Kim; Ji-Hwan Kim; Jae-Hong Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

9.  Effect of the Crystallization Process on the Marginal and Internal Gaps of Lithium Disilicate CAD/CAM Crowns.

Authors:  Jae-Hong Kim; Seunghan Oh; Soo-Hyuk Uhm
Journal:  Biomed Res Int       Date:  2016-03-31       Impact factor: 3.411

10.  Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study.

Authors:  Sujana Ullattuthodi; Kandathil Phillip Cherian; R Anandkumar; M Sreedevi Nambiar
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.