Literature DB >> 23680155

Analysis of the thoracic aorta using a semi-automated post processing tool.

Pegah Entezari1, Aya Kino, Amir R Honarmand, Mauricio S Galizia, Yan Yang, Jeremy Collins, Vahid Yaghmai, James C Carr.   

Abstract

OBJECTIVE: To evaluates a semi-automated method for Thoracic Aortic Aneurysm (TAA) measurement using ECG-gated Dual Source CT Angiogram (DSCTA).
METHODS: This retrospective HIPAA compliant study was approved by our IRB. Transaxial maximum diameters of outer wall to outer wall were studied in fifty patients at seven anatomic locations of the thoracic aorta: annulus, sinus, sinotubular junction (STJ), mid ascending aorta (MAA) at the level of right pulmonary artery, proximal aortic arch (PROX) immediately proximal to innominate artery, distal aortic arch (DIST) immediately distal to left subclavian artery, and descending aorta (DESC) at the level of diaphragm. Measurements were performed using a manual method and semi-automated software. All readers repeated their measurements. Inter-method, intra-observer and inter-observer agreements were evaluated according to intraclass correlation coefficient (ICC) and Bland-Altman plot. The number of cases with manual contouring or center line adjustment for the semi-automated method and also the post-processing time for each method were recorded.
RESULTS: The mean difference between semi-automated and manual methods was less than 1.3mm at all seven points. Strong inter-method, inter-observer and intra-observer agreement was recorded at all levels (ICC ≥ 0.9). The maximum rate of manual adjustment of center line and contour was at the level of annulus. The average time for manual post-processing of the aorta was 19 ± 0.3 min, while it took 8.26 ± 2.1 min to do the measurements with the semi-automated tool (Vitrea version 6.0.0.1 software). The center line was edited manually at all levels, with most corrections at the level of annulus (60%), while the contour was adjusted at all levels with highest and lowest number of corrections at the levels of annulus and DESC (75% and 0.07% of the cases), respectively.
CONCLUSION: Compared to the commonly used manual method, semi-automated measurement of vessel dimensions is feasible in the thoracic aorta with the advantage of reduced post-processing time.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  3D segmentation; Aortic aneurysm; Aortic luminal diameter measurement; CT Angiography; Quantitative analysis; Thoracic Aorta

Mesh:

Year:  2013        PMID: 23680155     DOI: 10.1016/j.ejrad.2013.03.024

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  7 in total

1.  Altered aortic shape in bicuspid aortic valve relatives influences blood flow patterns.

Authors:  Susanne Schnell; Danielle A Smith; Alex J Barker; Pegah Entezari; Amir R Honarmand; Maria L Carr; S Chris Malaisrie; Patrick M McCarthy; Jeremy Collins; James C Carr; Michael Markl
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2016-07-26       Impact factor: 6.875

2.  Automatic detection of anatomical landmarks of the aorta in CTA images.

Authors:  Pablo G Tahoces; Daniel Santana-Cedrés; Luis Alvarez; Miguel Alemán-Flores; Agustín Trujillo; Carmelo Cuenca; Jose M Carreira
Journal:  Med Biol Eng Comput       Date:  2020-02-19       Impact factor: 2.602

3.  Characterization of abnormal wall shear stress using 4D flow MRI in human bicuspid aortopathy.

Authors:  Pim van Ooij; Wouter V Potters; Jeremy Collins; Maria Carr; James Carr; S Chris Malaisrie; Paul W M Fedak; Patrick M McCarthy; Michael Markl; Alex J Barker
Journal:  Ann Biomed Eng       Date:  2014-08-14       Impact factor: 3.934

4.  Quantification of the Thoracic Aorta and Detection of Aneurysm at CT: Development and Validation of a Fully Automatic Methodology.

Authors:  Fabiola Bezerra de Carvalho Macruz; Charles Lu; Julia Strout; Angelo Takigami; Rupert Brooks; Sean Doyle; Min Yun; Varun Buch; Sandeep Hedgire; Brian Ghoshhajra
Journal:  Radiol Artif Intell       Date:  2022-02-23

5.  Automated 3D segmentation and diameter measurement of the thoracic aorta on non-contrast enhanced CT.

Authors:  Zahra Sedghi Gamechi; Lidia R Bons; Marco Giordano; Daniel Bos; Ricardo P J Budde; Klaus F Kofoed; Jesper Holst Pedersen; Jolien W Roos-Hesselink; Marleen de Bruijne
Journal:  Eur Radiol       Date:  2019-01-23       Impact factor: 5.315

6.  Assessing the Accuracy of an Artificial Intelligence-Based Segmentation Algorithm for the Thoracic Aorta in Computed Tomography Applications.

Authors:  Christoph Artzner; Malte N Bongers; Rainer Kärgel; Sebastian Faby; Gerald Hefferman; Judith Herrmann; Svenja L Nopper; Regine M Perl; Sven S Walter
Journal:  Diagnostics (Basel)       Date:  2022-07-23

7.  Comparability of semiautomatic tortuosity measurements in the carotid artery.

Authors:  Evelien E de Vries; Vanessa E C Pourier; Constance J H C M van Laarhoven; Evert J Vonken; Joost A van Herwaarden; Gert J de Borst
Journal:  Neuroradiology       Date:  2018-10-18       Impact factor: 2.804

  7 in total