| Literature DB >> 23677962 |
A Żyluk1, I Walaszek, Z Szlosser.
Abstract
A prospective study was carried out to investigate any correlation between electrophysiological and sonographic findings in patients with a clinical diagnosis of carpal tunnel syndrome. A total of 113 patients (113 wrists) in 90 women and 23 men, with a mean age of 60 years, underwent sonographic and electrophysiological examination. Fifty-five patients (48%) had mild, 43 (38%) moderate and 12 (11%) had severe conduction disturbances and three patients had normal conduction. Sonographic measurements showed a cross-sectional area of the median nerve of 9.9 mm(2) at the forearm and 17.8 mm(2) at the tunnel inlet. The mean anteroposterior diameter (height) of the nerve at the tunnel inlet was 2.7 mm, and the lowest height inside the tunnel was 1.8 mm. No correlation was found between sonographic and electrophysiological parameters.Entities:
Keywords: Carpal tunnel syndrome diagnosis; electrodiagnosis; ultrasonography
Mesh:
Year: 2013 PMID: 23677962 DOI: 10.1177/1753193413489046
Source DB: PubMed Journal: J Hand Surg Eur Vol ISSN: 0266-7681