Literature DB >> 23676259

A locking contoured plate for distal fibular fractures: mechanical evaluation in an osteoporotic bone model using screws of different length.

Robert K Zahn1, Michael Jakubietz, Sönke Frey, Stefanie Doht, Alexander Sauer, Rainer H Meffert.   

Abstract

Osteoporotic bone with poor mechanical capacity provides limited stability after fixation of ankle fractures. Stabilization with an implant providing increased fixation strength in osteoporotic bone could reduce failure rates of fixation and allow a more functional treatment. The purpose of this study was to evaluate a locking contoured plate for fixation of distal fibular fractures in comparison with a conventional contoured plate in an osteoporotic bone model. Eighty cylinders of osteoporotic bone surrogates were fixed with the two plates. We performed torque-to-failure and cyclic testing experiments using screws of different length with a Zwick/Roell testing machine. The locking system showed higher torque-to-failure and maximum torque levels as compared with the conventional plate in torque-to-failure experiments and torsional cyclic testing. The locking contoured plate provides improved fixation strength in the osteoporotic bone model. The locking system may be appropriate for fixation of distal fibular fractures, especially in osteoporotic bone with poor mechanical capacity.

Entities:  

Mesh:

Year:  2013        PMID: 23676259     DOI: 10.1123/jab.2013-0018

Source DB:  PubMed          Journal:  J Appl Biomech        ISSN: 1065-8483            Impact factor:   1.833


  4 in total

1.  Distal fibula oblique fracture fixation using one-third tubular plate with and without lag screw - A biomechanical study of stability.

Authors:  Gopikanthan Manoharan; Rohit Singh; Jan Herman Kuiper; Leonard Derek Martin Nokes
Journal:  J Orthop       Date:  2018-05-07

2.  Combination of mini locking plate and nitinol arched shape-memory connector for purely lateral malleolus fractures: technique and clinical results.

Authors:  Demeng Xia; Yuntong Zhang; Tianle Ou; Yang Wang; Zichen Hao; Panyu Zhou; Shuogui Xu
Journal:  Ann Transl Med       Date:  2020-12

3.  One-Third Tubular Plate Remains a Clinically Good Option in Danis-Weber Type B Distal Fibular Fracture Fixation.

Authors:  Jae Hoon Ahn; Sung Hyun Cho; Mingi Jeong; Yoon-Chung Kim
Journal:  Orthop Surg       Date:  2021-10-27       Impact factor: 2.071

Review 4.  Intramedullary fixation of distal fibular fractures: a systematic review of clinical and functional outcomes.

Authors:  Sameer Jain; Benjamin A Haughton; Christopher Brew
Journal:  J Orthop Traumatol       Date:  2014-10-11