The properties of human body phantoms used in calculations of electromagnetic fields exposure by wireless communication handsets or hand-operated industrial devices.

Patryk Zradziński1.   

Abstract

According to international guidelines, the assessment of biophysical effects of exposure to electromagnetic fields (EMF) generated by hand-operated sources needs the evaluation of induced electric field (E(in)) or specific energy absorption rate (SAR) caused by EMF inside a worker's body and is usually done by the numerical simulations with different protocols applied to these two exposure cases. The crucial element of these simulations is the numerical phantom of the human body. Procedures of E(in) and SAR evaluation due to compliance analysis with exposure limits have been defined in Institute of Electrical and Electronics Engineers standards and International Commission on Non-Ionizing Radiation Protection guidelines, but a detailed specification of human body phantoms has not been described. An analysis of the properties of over 30 human body numerical phantoms was performed which has been used in recently published investigations related to the assessment of EMF exposure by various sources. The differences in applicability of these phantoms in the evaluation of E(in) and SAR while operating industrial devices and SAR while using mobile communication handsets are discussed. The whole human body numerical phantom dimensions, posture, spatial resolution and electric contact with the ground constitute the key parameters in modeling the exposure related to industrial devices, while modeling the exposure from mobile communication handsets, which needs only to represent the exposed part of the human body nearest to the handset, mainly depends on spatial resolution of the phantom. The specification and standardization of these parameters of numerical human body phantoms are key requirements to achieve comparable and reliable results from numerical simulations carried out for compliance analysis against exposure limits or within the exposure assessment in EMF-related epidemiological studies.

Entities:  

Mesh:

Year:  2013        PMID: 23675626     DOI: 10.3109/15368378.2013.776434

Source DB:  PubMed          Journal:  Electromagn Biol Med        ISSN: 1536-8386            Impact factor:   2.882


  4 in total

1.  An In Situ and In Silico Evaluation of Biophysical Effects of 27 MHz Electromagnetic Whole Body Humans Exposure Expressed by the Limb Current.

Authors:  Jolanta Karpowicz; Patryk Zradziński; Jarosław Kieliszek; Krzysztof Gryz; Jaromir Sobiech; Wiesław Leszko
Journal:  Biomed Res Int       Date:  2017-07-05       Impact factor: 3.411

2.  Difficulties in applying numerical simulations to an evaluation of occupational hazards caused by electromagnetic fields.

Authors:  Patryk Zradziński
Journal:  Int J Occup Saf Ergon       Date:  2015

3.  An assessment of hazards caused by electromagnetic interaction on humans present near short-wave physiotherapeutic devices of various types including hazards for users of electronic active implantable medical devices (AIMD).

Authors:  Jolanta Karpowicz; Krzysztof Gryz
Journal:  Biomed Res Int       Date:  2013-09-08       Impact factor: 3.411

4.  An Evaluation of Electromagnetic Exposure While Using Ultra-High Frequency Radiofrequency Identification (UHF RFID) Guns.

Authors:  Patryk Zradziński; Jolanta Karpowicz; Krzysztof Gryz; Victoria Ramos
Journal:  Sensors (Basel)       Date:  2019-12-30       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.