Literature DB >> 23674791

Split-bolus spectral multidetector CT of the pancreas: assessment of radiation dose and tumor conspicuity.

Olga R Brook1, Sofia Gourtsoyianni, Alexander Brook, Bettina Siewert, Tara Kent, Vassilios Raptopoulos.   

Abstract

PURPOSE: To assess tumor conspicuity and radiation dose with a new multidetector computed tomography (CT) protocol for pancreatic imaging that combines spectral CT and split-bolus injection.
MATERIALS AND METHODS: This study was approved by the institutional review board and compliant with HIPAA. The requirement for informed consent was waived. One hundred sixty-three consecutive patients referred for possible pancreatic mass underwent CT with either a standard or split-bolus spectral CT protocol depending on scanner availability. Split-bolus spectral CT (CT unit with spectral imaging) combines pancreatic and portal venous phases in a single scan: 70 seconds before CT, 100 mL of contrast material is injected for the portal venous phase followed approximately 35 seconds later by injection of 40 mL of contrast material to boost the pancreatic phase. Bolus tracking after the second bolus initiates scanning 15 seconds after aorta enhancement reaches 280 HU. Images were reconstructed at 60 and 77 keV. The standard protocol (64-detector row unit) included unenhanced and pancreatic and portal venous phase imaging, with a single contrast material injection timed with bolus tracking 15 seconds after aortic enhancement of 300 HU for the pancreatic phase and 32 seconds later for the portal venous phase. Tumor conspicuity (difference in attenuation between tumor and pancreatic parenchyma) and contrast-to-noise ratio (CNR) were determined. Attenuation of aorta, main portal vein, and liver were measured. Patient size and per-examination radiation dose were recorded. The heteroscedastic t test, Fisher exact test, and Mann-Whitney test were used for statistical analysis.
RESULTS: There were no significant differences in age, weight, and body mass index between patients in the standard CT (46 of 80 patients had lesions) and split-bolus spectral CT (39 of 83 patients had lesions) groups; however, there were significantly more women in the split-bolus group (P = .02). Tumor conspicuity and CNR were higher with the 60-keV split-bolus protocol (89.1 HU ± 56.6 and 8.8 ± 6.2, respectively) than with the pancreatic or portal venous phase of the standard protocol (43.5 HU ± 28.4 and 4.5 ± 3.0, and 51.5 HU ± 30.3 and 5.6 ± 4.0, respectively; P < .01 for all comparisons). Dose-length product was 1112 mGy · cm ± 437 with the standard protocol and 633 mGy · cm ± 105 with the split-bolus protocol (P < .001).
CONCLUSION: Split-bolus spectral multidetector CT resulted in vascular, liver, and pancreatic attenuation and tumor conspicuity equal to or greater than that with multiphase CT, with a 43% reduction in radiation dose. © RSNA, 2013.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23674791     DOI: 10.1148/radiol.13121409

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  15 in total

Review 1.  White paper on pancreatic ductal adenocarcinoma from society of abdominal radiology's disease-focused panel for pancreatic ductal adenocarcinoma: Part II, update on imaging techniques and screening of pancreatic cancer in high-risk individuals.

Authors:  Naveen M Kulkarni; Lorenzo Mannelli; Marc Zins; Priya R Bhosale; Hina Arif-Tiwari; Olga R Brook; Elizabeth M Hecht; Fay Kastrinos; Zhen Jane Wang; Erik V Soloff; Parag P Tolat; Guillermo Sangster; Jason Fleming; Eric P Tamm; Avinash R Kambadakone
Journal:  Abdom Radiol (NY)       Date:  2020-03

2.  Quantitative and Qualitative Comparison of Single-Source Dual-Energy Computed Tomography and 120-kVp Computed Tomography for the Assessment of Pancreatic Ductal Adenocarcinoma.

Authors:  Priya Bhosale; Ott Le; Aprana Balachandran; Patricia Fox; Eric Paulson; Eric Tamm
Journal:  J Comput Assist Tomogr       Date:  2015 Nov-Dec       Impact factor: 1.826

Review 3.  Intraductal papillary mucinous neoplasm (IPMN) of the pancreas: recommendations for Standardized Imaging and Reporting from the Society of Abdominal Radiology IPMN disease focused panel.

Authors:  Elizabeth M Hecht; Gaurav Khatri; Desiree Morgan; Stella Kang; Priya R Bhosale; Isaac R Francis; Namita S Gandhi; David M Hough; Chenchan Huang; Lyndon Luk; Alec Megibow; Justin M Ream; Dushyant Sahani; Vahid Yaghmai; Atif Zaheer; Ravi Kaza
Journal:  Abdom Radiol (NY)       Date:  2020-11-13

4.  Spectral CT evaluation of interstitial brachytherapy in pancreatic carcinoma xenografts: preliminary animal experience.

Authors:  Shudong Hu; Wei Huang; Yerong Chen; Qi Song; Xiaozhu Lin; Zhongmin Wang; Kemin Chen
Journal:  Eur Radiol       Date:  2014-06-06       Impact factor: 5.315

5.  Dual bolus intravenous contrast injection technique for multiregion paediatric body CT.

Authors:  Karen E Thomas; E H Mann; N Padfield; L Greco; G BenDavid; A Alzahrani
Journal:  Eur Radiol       Date:  2014-11-24       Impact factor: 5.315

6.  Detection of small (≤ 2 cm) pancreatic adenocarcinoma and surrounding parenchyma: correlations between enhancement patterns at triphasic MDCT and histologic features.

Authors:  Michele Scialpi; Lucio Cagini; Luisa Pierotti; Francesco De Santis; Teresa Pusiol; Irene Piscioli; Michelle Magli; Alfredo D'Andrea; Luca Brunese; Antonio Rotondo
Journal:  BMC Gastroenterol       Date:  2014-01-21       Impact factor: 3.067

7.  Application of computed tomography virtual noncontrast spectral imaging in evaluation of hepatic metastases: a preliminary study.

Authors:  Shi-Feng Tian; Ai-Lian Liu; Jing-Hong Liu; Mei-Yu Sun; He-Qing Wang; Yi-Jun Liu
Journal:  Chin Med J (Engl)       Date:  2015-03-05       Impact factor: 2.628

8.  Dual-layer spectral CT improves image quality of multiphasic pancreas CT in patients with pancreatic ductal adenocarcinoma.

Authors:  Yasunori Nagayama; Shota Tanoue; Taihei Inoue; Seitaro Oda; Takeshi Nakaura; Daisuke Utsunomiya; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2019-07-16       Impact factor: 5.315

9.  Split-bolus versus triphasic multidetector-row computed tomography technique in the diagnosis of hepatic focal nodular hyperplasia: a case report.

Authors:  Michele Scialpi; Luisa Pierotti; Sabrina Gravante; Irene Piscioli; Teresa Pusiol; Raffaele Schiavone; Alfredo D'Andrea
Journal:  J Med Case Rep       Date:  2014-12-14

10.  Split-Bolus Single-Pass Multidetector-Row CT Protocol for Diagnosis of Acute Pulmonary Embolism.

Authors:  Michele Scialpi; Alberto Rebonato; Lucio Cagini; Luca Brunese; Irene Piscioli; Luisa Pierotti; Lucio Bellantonio; Alfredo D'Andrea; Antonio Rotondo
Journal:  Iran J Radiol       Date:  2016-01-14       Impact factor: 0.212