Automatic localization of the da Vinci surgical instrument tips in 3-D transrectal ultrasound.

Omid Mohareri1, Mahdi Ramezani, Troy K Adebar, Purang Abolmaesumi, Septimiu E Salcudean.   

Abstract

Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical system is the current state-of-the-art treatment option for clinically confined prostate cancer. Given the limited field of view of the surgical site in RALRP, several groups have proposed the integration of transrectal ultrasound (TRUS) imaging in the surgical workflow to assist with accurate resection of the prostate and the sparing of the neurovascular bundles (NVBs). We previously introduced a robotic TRUS manipulator and a method for automatically tracking da Vinci surgical instruments with the TRUS imaging plane, in order to facilitate the integration of intraoperative TRUS in RALRP. Rapid and automatic registration of the kinematic frames of the da Vinci surgical system and the robotic TRUS probe manipulator is a critical component of the instrument tracking system. In this paper, we propose a fully automatic registration technique based on automatic 3-D TRUS localization of robot instrument tips pressed against the air-tissue boundary anterior to the prostate. The detection approach uses a multiscale filtering technique to identify and localize surgical instrument tips in the TRUS volume, and could also be used to detect other surface fiducials in 3-D ultrasound. Experiments have been performed using a tissue phantom and two ex vivo tissue samples to show the feasibility of the proposed methods. Also, an initial in vivo evaluation of the system has been carried out on a live anaesthetized dog with a da Vinci Si surgical system and a target registration error (defined as the root mean square distance of corresponding points after registration) of 2.68 mm has been achieved. Results show this method's accuracy and consistency for automatic registration of TRUS images to the da Vinci surgical system.

Entities:  

Mesh:

Year:  2013        PMID: 23674418     DOI: 10.1109/TBME.2013.2262499

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  2 in total

1.  Design and Integration of a Parallel, Soft Robotic End-Effector for Extracorporeal Ultrasound.

Authors:  Lukas Lindenroth; Richard James Housden; Shuangyi Wang; Junghwan Back; Kawal Rhode; Hongbin Liu
Journal:  IEEE Trans Biomed Eng       Date:  2019-12-04       Impact factor: 4.538

2.  A Clamping Force Estimation Method Based on a Joint Torque Disturbance Observer Using PSO-BPNN for Cable-Driven Surgical Robot End-Effectors.

Authors:  Zhengyu Wang; Daoming Wang; Bing Chen; Lingtao Yu; Jun Qian; Bin Zi
Journal:  Sensors (Basel)       Date:  2019-12-01       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.