Literature DB >> 23674002

Added value of high-b-value (b = 3000 s/mm2) diffusion-weighted imaging at 3 T in relation to fluid-attenuated inversion recovery images for the evaluation of cortical lesions in inflammatory brain diseases.

Koya Iwashita1, Toshinori Hirai, Mika Kitajima, Yoshinori Shigematsu, Hiroyuki Uetani, Yasuhiko Iryo, Minako Azuma, Eri Hayashida, Yukio Ando, Ryuji Murakami, Yasuyuki Yamashita.   

Abstract

OBJECTIVE: The purpose of this study was to determine how the gray-to-white matter contrast in healthy subjects changes on high-b-value diffusion-weighted imaging (DWI) acquired at 3 T and evaluate whether high-b-value DWI at 3 T is useful for the detection of cortical lesions in inflammatory brain diseases.
METHODS: Ten healthy volunteers underwent DWI at b = 1000, 2000, 3000, 4000, and 5000 s/mm(2) on a 3-T MRI unit. On DW images, 1 radiologist performed region-of-interest measurements of the signal intensity of 8 gray matter structures. The gray-to-white matter contrast ratio (GWCR) was calculated. Ten patients with inflammatory cortical lesions were also included. All patients underwent conventional MRI and DWI at b = 1000 and 3000 s/mm(2). Using a 4-point grading system, 2 radiologists independently assessed the presence of additional information on DW images compared with fluid-attenuated inversion recovery images. Interobserver agreement was assessed by κ statistics.
RESULTS: In the healthy subjects, the b value increased as the GWCR decreased in all evaluated gray matter structures. On DW images acquired at b = 3000 s/mm(2), mean GWCR was less than 1.0 in 7 of 8 structures. For both reviewers, DWI at b = 3000 s/mm(2) yielded significantly more additional information than did DWI at b = 1000 s/mm(2) (P < 0.05). Interobserver agreement for DWI at b = 1000 s/mm(2) and b = 3000 s/mm(2) was fair (κ = 0.35) and excellent (κ = 1.0), respectively.
CONCLUSIONS: At 3-T DWI, the gray-to-white matter contrast in most gray matter structures reverses at b = 3000 s/mm. In the evaluation of cortical lesions in patients with inflammatory brain diseases, 3-T DWI at b = 3000 s/mm was more useful than b = 1000 s/mm(2).

Entities:  

Mesh:

Year:  2013        PMID: 23674002     DOI: 10.1097/RCT.0b013e318288a661

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  1 in total

1.  Benefit of 3T Diffusion-weighted Imaging in Comparison to Contrast-enhanced MR Imaging for the Evaluation of Disseminated Lesions in Primary Malignant Brain Tumors.

Authors:  Yoshihito Kadota; Toshinori Hirai; Hideo Nakamura; Keishi Makino; Shigetoshi Yano; Shinichiro Nishimura; Machiko Tateishi; Minako Azuma; Mika Kitajima; Yasuyuki Yamashita
Journal:  Magn Reson Med Sci       Date:  2016-10-11       Impact factor: 2.471

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.