Effectiveness of commonly available surface protecting agents in maintaining microhardness of two cements.

Nazish Fatima1, Syed Yawar Ali Abidi, Fazal-ur-Rehaman Qazi, Shahbaz Ahmed Jat.   

Abstract

OBJECTIVE: To estimate the microhardness of glass ionomer cement (vitrofil) and resin modified glass ionomer cement (vitremere) in the presence and absence of different surface protections. STUDY
DESIGN: An in-vitro experimental study. PLACE AND DURATION OF STUDY: The Department of Operative Dentistry, Dr. Ishrat-ul-Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences and the Department of Material Sciences, NED University, Karachi, from August 2011 to January 2012.
METHODOLOGY: Seventy-two discs of each material were made in polytetrafluoroethylene mold which was 10 mm in diameter and 2 mm in thickness. Four groups were made for each material containing 18 discs; G1/G5 (control group), G2/G6 (solid petroleum jelly), G3/G7 vernal (resin varnish), G4/G8 (nail varnish). After initial setting reaction surface protection was applied to discs. Once the surface protection was dried, discs were stored in deionized water at 37°C for 24 hours. After 24 hours, the discs were polished. Microhardness test were performed in digital microhardness tester. The results were statistically analyzed with the help of two-way ANOVA.
RESULTS: For glass ionomer cement the only G4 (nail varnish) differed from the G1 (control group) [p < 0.05], No significant difference was seen with other surface protection agents. For resin modified glass ionomer cement, the G7 (resin varnish) and G8 (nail varnish) gave better result from the G5 (control group).
CONCLUSION: Nail varnish and resin varnish showed better surface protection for GIC and RMGIC. The presence of toluene in nail varnish have harmful effects so should not be preferred if resin varnish is available.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23673167     DOI: 05.2013/JCPSP.314318

Source DB:  PubMed          Journal:  J Coll Physicians Surg Pak        ISSN: 1022-386X            Impact factor:   0.711


  4 in total

1.  In vitro abrasion of resin-coated highly viscous glass ionomer cements: a confocal laser scanning microscopy study.

Authors:  Özgur Kanik; L Sebnem Turkun; Walter Dasch
Journal:  Clin Oral Investig       Date:  2016-04-13       Impact factor: 3.573

2.  Protective effect of a nanofilled resin-based coating on wear resistance of glass ionomer cement restorative materials.

Authors:  Milad Moghimi; Dana Jafarpour; Reihaneh Ferooz; Rafat Bagheri
Journal:  BMC Oral Health       Date:  2022-07-30       Impact factor: 3.747

3.  Clinical wear of approximal glass ionomer restorations protected with a nanofilled self-adhesive light-cured protective coating.

Authors:  Daniela Hesse; Clarissa Calil Bonifácio; Cornelis Johannes Kleverlaan; Daniela Prócida Raggio
Journal:  J Appl Oral Sci       Date:  2018-10-04       Impact factor: 2.698

4.  A comparative evaluation of resin- and varnish-based surface protective agents on glass ionomer cement - a spectrophotometric analysis.

Authors:  Shreya Tyagi; Abi M Thomas; Neeta Devi Sinnappah-Kang
Journal:  Biomater Investig Dent       Date:  2020-01-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.