Literature DB >> 23670990

DTI of human skeletal muscle: the effects of diffusion encoding parameters, signal-to-noise ratio and T2 on tensor indices and fiber tracts.

Martijn Froeling1, Aart J Nederveen, Klaas Nicolay, Gustav J Strijkers.   

Abstract

In this study, we have performed simulations to address the effects of diffusion encoding parameters, signal-to-noise ratio (SNR) and T2 on skeletal muscle diffusion tensor indices and fiber tracts. Where appropriate, simulations were corroborated and validated by in vivo diffusion tensor imaging (DTI) of human skeletal muscle. Specifically, we have addressed: (i) the accuracy and precision of the diffusion parameters and eigenvectors at different SNR levels; (ii) the effects of the diffusion gradient direction encoding scheme; (iii) the optimal b value for diffusion tensor estimation; (iv) the effects of changes in skeletal muscle T2; and, finally, the influence of SNR on fiber tractography and derived (v) fiber lengths, (vi) pennation angles and (vii) fiber curvatures. We conclude that accurate DTI of skeletal muscle requires an SNR of at least 25, a b value of between 400 and 500 s/mm(2), and data acquired with at least 12 diffusion gradient directions homogeneously distributed on half a sphere. Furthermore, for DTI studies focusing on skeletal muscle injury or pathology, apparent changes in the diffusion parameters need to be interpreted with great care in view of the confounding effects of T2, particularly for moderate to low SNR values.
Copyright © 2013 John Wiley & Sons, Ltd.

Entities:  

Keywords:  diffusion encoding parameters; diffusion tensor imaging; fiber tractography; signal-to-noise ratio; simulation; skeletal muscle

Mesh:

Year:  2013        PMID: 23670990     DOI: 10.1002/nbm.2959

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  43 in total

1.  Assessment of diffusion tensor imaging indices in calf muscles following postural change from standing to supine position.

Authors:  Alyaa H Elzibak; Michael D Noseworthy
Journal:  MAGMA       Date:  2013-12-03       Impact factor: 2.310

2.  Dynamic diffusion-tensor measurements in muscle tissue using the single-line multiple-echo diffusion-tensor acquisition technique at 3T.

Authors:  Steven H Baete; Gene Y Cho; Eric E Sigmund
Journal:  NMR Biomed       Date:  2015-04-22       Impact factor: 4.044

3.  Muscle diffusion tensor imaging in glycogen storage disease V (McArdle disease).

Authors:  R Rehmann; L Schlaffke; M Froeling; R A Kley; E Kühnle; M De Marées; J Forsting; M Rohm; M Tegenthoff; T Schmidt-Wilcke; M Vorgerd
Journal:  Eur Radiol       Date:  2018-12-17       Impact factor: 5.315

4.  Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease.

Authors:  Bruce M Damon; Ke Li; Richard D Dortch; E Brian Welch; Jane H Park; Amanda K W Buck; Theodore F Towse; Mark D Does; Daniel F Gochberg; Nathan D Bryant
Journal:  J Vis Exp       Date:  2016-12-18       Impact factor: 1.355

5.  Multi-parametric MRI characterization of healthy human thigh muscles at 3.0 T - relaxation, magnetization transfer, fat/water, and diffusion tensor imaging.

Authors:  Ke Li; Richard D Dortch; E Brian Welch; Nathan D Bryant; Amanda K W Buck; Theodore F Towse; Daniel F Gochberg; Mark D Does; Bruce M Damon; Jane H Park
Journal:  NMR Biomed       Date:  2014-07-26       Impact factor: 4.044

6.  Quantifying precision in cardiac diffusion tensor imaging with second-order motion-compensated convex optimized diffusion encoding.

Authors:  Eric Aliotta; Kévin Moulin; Patrick Magrath; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

Review 7.  Skeletal Muscle Quantitative Nuclear Magnetic Resonance Imaging and Spectroscopy as an Outcome Measure for Clinical Trials.

Authors:  Pierre G Carlier; Benjamin Marty; Olivier Scheidegger; Paulo Loureiro de Sousa; Pierre-Yves Baudin; Eduard Snezhko; Dmitry Vlodavets
Journal:  J Neuromuscul Dis       Date:  2016-03-03

8.  Multi-parametric MRI characterization of inflammation in murine skeletal muscle.

Authors:  Nathan D Bryant; Ke Li; Mark D Does; Stephanie Barnes; Daniel F Gochberg; Thomas E Yankeelov; Jane H Park; Bruce M Damon
Journal:  NMR Biomed       Date:  2014-04-29       Impact factor: 4.044

9.  Comparison of twice refocused spin echo versus stimulated echo diffusion tensor imaging for tracking muscle fibers.

Authors:  Brian Noehren; Anders Andersen; Thorsten Feiweier; Bruce Damon; Peter Hardy
Journal:  J Magn Reson Imaging       Date:  2014-02-19       Impact factor: 4.813

10.  Age-related differences in the response of leg muscle cross-sectional area and water diffusivity measures to a period of supine rest.

Authors:  Amanda L Lorbergs; Michael D Noseworthy; Norma J MacIntyre
Journal:  MAGMA       Date:  2014-10-15       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.