Predictors of pacemaker dependence and pacemaker dependence as a predictor of mortality in patients with implantable cardioverter defibrillator.

Nitesh Sood1, Eric Crespo, Meir Friedman, Danette Guertin, Steven Zweibel, Jeffrey Kluger, Christopher A Clyne.   

Abstract

BACKGROUND: The prevalence, predictors, and survival for the development of pacemaker dependence (PD) in patients implanted with an implantable cardioverter defibrillator (ICD) are unknown.
METHODS: This was a retrospective analysis of 1,550 consecutive patients with ICD implantation at a single center from 1996 to 2008 with a mean of 4.2 ± 3.4 years. Patients with implant intrinsic heart rates less than 40 beats/min (n = 48) and cardiac resynchronization therapy (n = 444) were excluded leaving 1,058 patients in this study. PD was defined as an intrinsic rhythm <40 beats/min after inhibiting the pacemaker, <50 beats/min with transient symptoms of dizziness relieved by resumption of pacing and right ventricle pacing despite algorithms to promote intrinsic conduction at the 3 monthly follow-up ICD clinic visits. Multivariate regression and Cox proportional hazard models were used for analysis.
RESULTS: The mean age was 64 ± 13 years; 79% were male with a primary indication for the ICD in 57%. PD occurred in 142 (13.4%) of patients, with a mean time to PD of 2.6 ± 1.9 years. PD was associated with a 48% increased odds for mortality versus non-PD ICD patients during the mean follow-up time of 4.2 ± 3.4 years (adjusted odds ratio = 1.48 [95% confidence interval 1.080-2.042]; P = 0.015). Older age, a history of atrial fibrillation, amiodarone use, and secondary prevention were the strongest predictors for the development of PD.
CONCLUSIONS: In this single-center ICD cohort, the development of PD was not uncommon and was associated with decreased survival. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  defibrillation - ICD; electrophysiology - clinical

Mesh:

Year:  2013        PMID: 23668483     DOI: 10.1111/pace.12164

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  1 in total

1.  Unexpected inhibition of bradycardia pacing due to oversensing in ICD lead fracture associated with spurious tachyarrhythmia detection and discharges.

Authors:  Fani Zagkli; Panagiotis Chronopoulos; John Chiladakis
Journal:  Indian Pacing Electrophysiol J       Date:  2021-03-02