Literature DB >> 23665648

Preconditioned donor corneal thickness for microthin endothelial keratoplasty.

Peter B M Thomas1, Achyut N Mukherjee, Dominic O'Donovan, Madhavan S Rajan.   

Abstract

PURPOSE: To describe a novel surgical technique to produce thin endothelial grafts for Descemet stripping automated endothelial keratoplasty (DSAEK).
METHODS: Thirteen human cadaveric corneas in organ culture were randomized into conventional (n = 7) and microthin (n = 6) DSAEK groups. Grafts in the conventional DSAEK group were prepared using the conventional DSAEK technique of a single microkeratome pass with a 350-μm cutting head. Corneas in the microthin group were preconditioned to achieve a target central thickness of 530 μm before graft dissection with a 350-μm microkeratome head. Preconditioning involved stromal dehydration under pachymetric control using sterile airflow for 15-second increments. Donor and graft thicknesses were assessed with optical coherence tomography, and endothelial viability with trypan blue and alizarin red staining.
RESULTS: Mean endothelial graft thickness obtained using the microthin DSAEK technique was 106 μm (SD, 32 μm) compared with 177 μm (SD, 33 μm) obtained using conventional DSAEK technique (P = 0.0024). Donor preconditioning yielded a predicted reduction of 100 μm in graft stromal thickness at a rate of 1.5 μm/s and mean duration of 72 seconds. The average anterior lamella thickness (cut depth) obtained in microthin and conventional DSAEK groups were 424 and 431 μm, respectively (P = 0.84). There was no difference in endothelial viability between the 2 groups. There were no corneal perforations during graft preparation in this study.
CONCLUSIONS: Donor preconditioning by pachymetry-controlled stromal dehydration achieved significantly thinner endothelial grafts compared with the conventional DSAEK technique without compromise to endothelial viability or graft wastage.

Entities:  

Mesh:

Year:  2013        PMID: 23665648     DOI: 10.1097/ICO.0b013e3182912fd2

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  4 in total

Review 1.  Surgical strategies to improve visual outcomes in corneal transplantation.

Authors:  M S Rajan
Journal:  Eye (Lond)       Date:  2014-01-03       Impact factor: 3.775

Review 2.  Evolution of therapies for the corneal endothelium: past, present and future approaches.

Authors:  Hon Shing Ong; Marcus Ang; Jodhbir Mehta
Journal:  Br J Ophthalmol       Date:  2020-07-24       Impact factor: 4.638

Review 3.  Use of biomaterials in corneal endothelial repair.

Authors:  Noor Ahmed Hussain; Francisco C Figueiredo; Che J Connon
Journal:  Ther Adv Ophthalmol       Date:  2021-12-23

4.  Effect of vital dyes on human corneal endothelium and elasticity of Descemet's membrane.

Authors:  Isabell P Weber; Mrinal Rana; Peter B M Thomas; Ivan B Dimov; Kristian Franze; Madhavan S Rajan
Journal:  PLoS One       Date:  2017-09-13       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.