Literature DB >> 23665644

Correlation of anterior and posterior corneal shape in keratoconus.

Raúl Montalbán1, Jorge L Alio, Jaime Javaloy, David P Piñero.   

Abstract

PURPOSE: To evaluate the correlation of the mean curvature and shape factors of both corneal surfaces for different corneal diameters measured with the Scheimpflug photography-based system in keratoconus eyes.
METHODS: A total of 61 keratoconus eyes of 61 subjects, aged 14 to 64 years, were included in this study. All eyes received a comprehensive ophthalmologic examination including anterior segment and corneal analysis with the Sirius system (CSO): anterior and posterior mean corneal radius for 3, 5, and 7 mm (aKM, pKM), anterior and posterior mean shape factor for 4.5 and 8 mm (ap, pp), central and minimal corneal thickness, and anterior chamber depth.
RESULTS: Mean aKM/pKM ratio around 1.20 (range, 0.95-1.48) was found for all corneal diameters (P = 0.24). Weak but significant correlations of this ratio with pachymetric parameters were found (r between -0.28 and -0.34, P < 0.04). The correlation coefficient between aKM and pKM was ≥ 0.92 for all corneal diameters. A strong and significant correlation was also found between ap and pp (r ≥ 0.86, P < 0.01). The multiple regression analysis revealed that central pKM was significantly correlated with aKM, central corneal thickness, anterior chamber depth, and spherical equivalent (R ≥ 0.88, P < 0.01) and that 8 mm pp was significantly correlated with 8 mm ap and age (R = 0.89, P < 0.01).
CONCLUSIONS: Central posterior corneal curvature and shape factor in the keratoconus eye can be consistently predicted from the anterior corneal curvature and shape factor, respectively, in combination with other anatomical and ocular parameters.

Entities:  

Mesh:

Year:  2013        PMID: 23665644     DOI: 10.1097/ICO.0b013e3182904950

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  8 in total

Review 1.  Corneal topography in keratoconus: state of the art.

Authors:  F Cavas-Martínez; E De la Cruz Sánchez; J Nieto Martínez; F J Fernández Cañavate; D G Fernández-Pacheco
Journal:  Eye Vis (Lond)       Date:  2016-02-22

2.  Preliminary validation of an optimized algorithm for intraocular lens power calculation in keratoconus.

Authors:  Vicente J Camps; David P Piñero; Esteban Caravaca; Dolores De Fez
Journal:  Indian J Ophthalmol       Date:  2017-08       Impact factor: 1.848

3.  Analysis of total corneal astigmatism with a rotating Scheimpflug camera in keratoconus.

Authors:  Jinho Kim; Woong-Joo Whang; Hyun-Seung Kim
Journal:  BMC Ophthalmol       Date:  2020-12-03       Impact factor: 2.209

4.  A new approach to keratoconus detection based on corneal morphogeometric analysis.

Authors:  Francisco Cavas-Martínez; Laurent Bataille; Daniel G Fernández-Pacheco; Francisco J F Cañavate; Jorge L Alió
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

5.  Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes.

Authors:  Young Choi; Youngsub Eom; Jong Suk Song; Hyo Myung Kim
Journal:  Korean J Ophthalmol       Date:  2018-05-15

6.  Algorithm for Correcting the Keratometric Error in the Estimation of the Corneal Power in Keratoconus Eyes after Accelerated Corneal Collagen Crosslinking.

Authors:  David P Piñero; Vicente J Camps; Esteban Caravaca-Arens; Dolores de Fez; Francisco J Blanes-Mompó
Journal:  J Ophthalmol       Date:  2017-10-22       Impact factor: 1.909

7.  Study and characterization of morphogeometric parameters to assist diagnosis of keratoconus.

Authors:  Francisco Cavas-Martínez; Daniel G Fernández-Pacheco; Dolores Parras; Francisco J F Cañavate; Laurent Bataille; Jorge Alió
Journal:  Biomed Eng Online       Date:  2018-11-20       Impact factor: 2.819

8.  Assessment of the Association between In Vivo Corneal Morphogeometrical Changes and Keratoconus Eyes with Severe Visual Limitation.

Authors:  J S Velázquez; F Cavas; J Alió Del Barrio; D G Fernández-Pacheco; J Alió
Journal:  J Ophthalmol       Date:  2019-09-22       Impact factor: 1.909

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.