Literature DB >> 23665063

Pattern description and reliability parameters of six force-time related indices measured with plantar pressure measurements.

Kevin Deschamps1, Philip Roosen, Herman Bruyninckx, Kaat Desloovere, Paul-Andre Deleu, Giovanni A Matricali, Louis Peeraer, Filip Staes.   

Abstract

BACKGROUND: Functional interpretation of plantar pressure measurements is commonly done through the use of ratios and indices which are preceded by the strategic combination of a subsampling method and selection of physical quantities. However, errors which may arise throughout the determination of these temporal indices/ratio calculations (T-IRC) have not been quantified. The purpose of the current study was therefore to estimate the reliability of T-IRC following semi-automatic total mapping (SATM).
METHODS: Using a repeated-measures design, two experienced therapists performed three subsampling sessions on three left and right pedobarographic footprints of ten healthy participants. Following the subsampling, six T-IRC were calculated: Rearfoot-Forefoot_fti, Rearfoot-Midfoot_fti, Forefoot medial/lateral_fti, First ray_fti, Metatarsal 1-Metatarsal 5_fti, Foot medial-lateral_fti.
FINDINGS: Patterns of the T-IRC were found to be consistent and in good agreement with corresponding knowledge from the literature. The inter-session errors of both therapists were similar in pattern and magnitude. The lowest peak inter-therapist error was found in the First ray_fti (6.5 a.u.) whereas the highest peak inter-therapist error was observed in the Forefoot medial/lateral_fti (27.0 a.u.) The magnitude of the inter-session and inter-therapist error varied over time, precluding the calculation of a simple numerical value for the error. The difference between both error parameters of all T-IRC was negligible which underscores the repeatability of the SATM protocol.
CONCLUSION: The current study reports consistent patterns for six T-IRC and similar inter-session and inter-therapist error. The proposed SATM protocol and the T-IRC may therefore serve as basis for functional interpretation of footprint data.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Footprint; Force–time related indices; Plantar pressure; Reliability

Mesh:

Year:  2013        PMID: 23665063     DOI: 10.1016/j.gaitpost.2013.04.003

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  1 in total

1.  Classification of forefoot plantar pressure distribution in persons with diabetes: a novel perspective for the mechanical management of diabetic foot?

Authors:  Kevin Deschamps; Giovanni Arnoldo Matricali; Philip Roosen; Kaat Desloovere; Herman Bruyninckx; Pieter Spaepen; Frank Nobels; Jos Tits; Mieke Flour; Filip Staes
Journal:  PLoS One       Date:  2013-11-22       Impact factor: 3.240