Literature DB >> 23664802

Three-dimensional facial anthropometry of unilateral cleft lip infants with a structured light scanning system.

Guanghui Li1, Jianhua Wei, Xi Wang, Guofeng Wu, Dandan Ma, Bo Wang, Yanpu Liu, Xinghua Feng.   

Abstract

BACKGROUND: Cleft lip in the presence or absence of a cleft palate is a major public health problem. However, few studies have been published concerning the soft-tissue morphology of cleft lip infants. Currently, obtaining reliable three-dimensional (3D) surface models of infants remains a challenge. The aim of this study was to investigate a new way of capturing 3D images of cleft lip infants using a structured light scanning system. In addition, the accuracy and precision of the acquired facial 3D data were validated and compared with direct measurements. STUDY
DESIGN: Ten unilateral cleft lip patients were enrolled in the study. Briefly, 3D facial images of the patients were acquired using a 3D scanner device before and after the surgery. Fourteen items were measured by direct anthropometry and 3D image software. The accuracy and precision of the 3D system were assessed by comparative analysis.
RESULTS: The anthropometric data obtained using the 3D method were in agreement with the direct anthropometry measurements. All data calculated by the software were 'highly reliable' or 'reliable', as defined in the literature. The localisation of four landmarks was not consistent in repeated experiments of inter-observer reliability in preoperative images (P<0.05), while the intra-observer reliability in both pre- and postoperative images was good (P>0.05).
CONCLUSIONS: The structured light scanning system is proven to be a non-invasive, accurate and precise method in cleft lip anthropometry.
Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Accuracy and precision; Anthropometry; Cleft lip; Infant; Three-dimensional facial imaging

Mesh:

Year:  2013        PMID: 23664802     DOI: 10.1016/j.bjps.2013.04.007

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  4 in total

1.  Scan time, reliability and accuracy of craniofacial measurements using a 3D light scanner.

Authors:  Camilla Franco de Sá Gomes; Mylena Ranieri Libdy; David Normando
Journal:  J Oral Biol Craniofac Res       Date:  2019-07-07

2.  Accuracy and precision of integumental linear dimensions in a three-dimensional facial imaging system.

Authors:  Soo-Hwan Kim; Woo-Young Jung; Yu-Jin Seo; Kyung-A Kim; Ki-Ho Park; Young-Guk Park
Journal:  Korean J Orthod       Date:  2015-05-15       Impact factor: 1.372

3.  Accuracy of three-dimensional photogrammetry and cone beam computed tomography based on linear measurements in patients with facial deformities.

Authors:  Zhenqi Zhao; Lizhe Xie; Dan Cao; Iman Izadikhah; Pengcheng Gao; Yang Zhao; Bin Yan
Journal:  Dentomaxillofac Radiol       Date:  2020-08-13       Impact factor: 2.419

4.  Linear accuracy of cone-beam computed tomography and a 3-dimensional facial scanning system: An anthropomorphic phantom study.

Authors:  Song Hee Oh; Ju Hee Kang; Yu-Kyeong Seo; Sae Rom Lee; Hwa-Young Choi; Yong-Suk Choi; Eui-Hwan Hwang
Journal:  Imaging Sci Dent       Date:  2018-06-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.