Implant-abutment gap versus microbial colonization: Clinical significance based on a literature review.

Sheila Pestana Passos1, Liliana Gressler May, Renata Faria, Mutlu Özcan, Marco Antonio Bottino.   

Abstract

Microorganisms from the oral cavity may settle at the implant-abutment interface (IAI). As a result, tissue inflammation could occur around these structures. The databases MEDLINE/PubMed and PubMed Central were used to identify articles published from 1981 through 2012 related to the microbial colonization in the implant-abutment gap and its consequence in terms of crest bone loss and osseointegration. The following considerations could be put forward, with respect to the clinical importance of IAI: (a) the space present at the IAI seems to allow bacterial leakage to occur, in spite of the size of this space; (b) bacterial leakage seems to occur at the IAI, irrespective of the type of connection. More studies are necessary to clarify the relationship between leakage at IAI and abutment connection designs; (c) losses at the peri-implant bone crests cannot be related to the IAI size, since few studies have shown no relationship. Also, the microbial leakage at the IAI cannot be related to the bone crest loss, since there are no articles reporting this relationship; remains controversial the influence of the IAI position on the bone crest losses.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  bone loss; implant-abutment connection; implant-abutment gap; microbial leakage; osseointegration

Mesh:

Substances:

Year:  2013        PMID: 23661560     DOI: 10.1002/jbm.b.32945

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  8 in total

Review 1.  Microleakage at the Different Implant Abutment Interface: A Systematic Review.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary; Shail Kumari
Journal:  J Clin Diagn Res       Date:  2017-06-01

2.  Oral bacterial colonization on dental implants restored with titanium or zirconia abutments: 6-month follow-up.

Authors:  Alice Ramos de Freitas; Thalisson Saymo de Oliveira Silva; Ricardo Faria Ribeiro; Rubens Ferreira de Albuquerque Junior; Vinícius Pedrazzi; Cássio do Nascimento
Journal:  Clin Oral Investig       Date:  2018-01-18       Impact factor: 3.573

3.  Impact of Dynamic Loading on the Implant-abutment Interface Using a Gas-enhanced Permeation Test In Vitro.

Authors:  Anas Al-Jadaa; Thomas Attin; Timo Peltomäki; Christian Heumann; Patrick Roger Schmidlin
Journal:  Open Dent J       Date:  2015-03-31

4.  In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection.

Authors:  Hooman Khorshidi; Saeed Raoofi; Afagh Moattari; Atoosa Bagheri; Mohammad Hassan Kalantari
Journal:  Int J Biomater       Date:  2016-05-03

5.  Mechanical Outcomes, Microleakage, and Marginal Accuracy at the Implant-Abutment Interface of Original versus Nonoriginal Implant Abutments: A Systematic Review of In Vitro Studies.

Authors:  Marco Tallarico; Joseph Fiorellini; Yasushi Nakajima; Yuki Omori; Iida Takahisa; Luigi Canullo
Journal:  Biomed Res Int       Date:  2018-12-30       Impact factor: 3.411

6.  Impact of crestal and subcrestal implant placement in peri-implant bone: A prospective comparative study.

Authors:  Hilario Pellicer-Chover; María Peñarrocha-Diago; David Peñarrocha-Oltra; Sonia Gomar-Vercher; Rubén Agustín-Panadero; Miguel Peñarrocha-Diago
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-01-01

7.  In situ microradioscopy and microtomography of fatigue-loaded dental two-piece implants.

Authors:  Wolfram Wiest; Simon Zabler; Alexander Rack; Christian Fella; Andreas Balles; Katja Nelson; Rainer Schmelzeisen; Randolf Hanke
Journal:  J Synchrotron Radiat       Date:  2015-10-09       Impact factor: 2.616

8.  Antibacterial effect of nanocurcumin inside the implant fixture: An in vitro study.

Authors:  Ramin Negahdari; Mohammad Ali Ghavimi; Ali Barzegar; Mohammad Yousef Memar; Ladan Balazadeh; Sepideh Bohlouli; Simin Sharifi; Solmaz Maleki Dizaj
Journal:  Clin Exp Dent Res       Date:  2020-11-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.