Literature DB >> 23659233

A new slant on toric intraocular lens power calculation.

Giacomo Savini1, Kenneth J Hoffer, Pietro Ducoli.   

Abstract

PURPOSE: The AcrySof Toric intraocular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX) is designed to correct corneal astigmatism ranging from 0.67 to 4.11 diopters (D). The authors reviewed the clinical outcomes of this IOL and investigated possible improvements of the online calculator provided by the manufacturer.
METHODS: Review of published studies.
RESULTS: The AcrySof Toric IOL can provide good results, although a mean overcorrection or undercorrection relative to the intended correction has been found by some authors. Stability over time has been reported to be excellent. Rotation occurs mainly in the first postoperative month and is greater in eyes with a longer axial length due to the larger capsule size. The online calculator of this IOL may be improved by considering the posterior corneal astigmatism and better calculating the conversion of the IOL cylinder from the IOL plane to the corneal plane, which may be inaccurate for two reasons. First, given the variable distance between the IOL and the cornea in short and long eyes, the fixed ratio (1.46) provided by the manufacturer cannot be used to calculate this conversion. Second, the online calculator does not take into account the effect of varying IOL sphere power.
CONCLUSION: The AcrySof Toric IOL is a reliable choice to correct corneal astigmatism at the time of cataract surgery. Results will be improved once the online calculator by the manufacturer considers the posterior corneal astigmatism and the variable ratio between the toricity at the IOL and corneal plane. Copyright 2013, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23659233     DOI: 10.3928/1081597X-20130415-06

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  6 in total

1.  Correction of low corneal astigmatism in cataract surgery.

Authors:  Pia Leon; Marco Rocco Pastore; Andrea Zanei; Ingrid Umari; Meriem Messai; Corrado Negro; Daniele Tognetto
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

2.  Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators.

Authors:  Hyun Ju Park; Hun Lee; Young Jae Woo; Eung Kweon Kim; Kyoung Yul Seo; Ha Yan Kim; Tae-im Kim
Journal:  Yonsei Med J       Date:  2015-07       Impact factor: 2.759

3.  The effect of corneal irregularity on astigmatism measurement by automated versus ray tracing keratometry.

Authors:  Hyun Cheol Roh; Roy S Chuck; Jimmy K Lee; Choul Yong Park
Journal:  Medicine (Baltimore)       Date:  2015-04       Impact factor: 1.889

Review 4.  Optimizing outcomes with toric intraocular lenses.

Authors:  Manpreet Kaur; Farin Shaikh; Ruchita Falera; Jeewan S Titiyal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

5.  Comparison of the clinical efficacy of AcrySof® IQ and TECNIS® toric intraocular lenses: A real-world study.

Authors:  Juan-Juan Yang; Ya-Zhou Qin; Li Qin; Jing-Ming Li
Journal:  Exp Ther Med       Date:  2020-08-28       Impact factor: 2.447

6.  Clinical Outcomes of Toric Intraocular Lenses: Differences in Expected Outcomes When Using a Calculator That Considers Effective Lens Position and the Posterior Cornea vs One That Does Not.

Authors:  Elizabeth Yeu; Albert Y Cheung; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2020-03-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.