Literature DB >> 23657406

Rat subcutaneous tissue response to MTA Fillapex® and Portland cement.

Nádia Carolina Teixeira Marques1, Natalino Lourenço Neto, Ana Paula Fernandes, Camila de Oliveira Rodini, Marco Antônio Hungaro Duarte, Thais Marchini Oliveira.   

Abstract

The aim of this study was to evaluate the response of rat subcutaneous tissue to MTA Fillapex® (Angelus), an experimental root canal filling material based on Portland cement and propylene glycol (PCPG), and a zinc oxide, eugenol and iodoform (ZOEI) paste. These materials were placed in polyethylene tubes and implanted into the dorsal connective tissue of Wistar rats for 7 and 15 days. The specimens were stained with hematoxylin and eosin, and evaluated regarding inflammatory reaction parameters by optical microscopy. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated examiners for all experimental periods (kappa=0.96). The histological evaluation showed that all materials caused a moderate inflammatory reaction at 7 days, which subsided with time. A greater inflammatory reaction was observed at 7 days in the tubes filled with ZOEI paste. Tubes filled with MTA Fillapex presented some giant cells, macrophages and lymphocytes after 7 days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The tubes filled with PCPG showed similar results to those observed in MTA Fillapex. At 15 days, the inflammatory reaction was almost absent at the tissue, with several collagen fibers indicating normal tissue healing. Data were analyzed by the nonparametric Kruskal-Wallis test (α=0.05). Statistically significant difference (p<0.05) was found only between PCPG at 15 days and ZOEI at 7 days groups. No significant differences were observed among the other groups/periods (p>0.05). MTA Fillapex and Portland cement added with propylene glycol had greater tissue compatibility than the PCPG paste.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23657406     DOI: 10.1590/0103-6440201302120

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  2 in total

1.  Immunoinflammatory response and bioactive potential of GuttaFlow bioseal and MTA Fillapex in the rat subcutaneous tissue.

Authors:  Mateus Machado Delfino; Juliane Maria Guerreiro-Tanomaru; Mário Tanomaru-Filho; Estela Sasso-Cerri; Paulo Sérgio Cerri
Journal:  Sci Rep       Date:  2020-04-28       Impact factor: 4.379

Review 2.  Portland Cement: An Overview as a Root Repair Material.

Authors:  Shahriar Shahi; Elaheh Fakhri; Hamidreza Yavari; Solmaz Maleki Dizaj; Sara Salatin; Khadijeh Khezri
Journal:  Biomed Res Int       Date:  2022-01-06       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.