Test-retest reliability of the Swedish version of the Orthotics and Prosthetics Users' Survey.

Gustav Jarl1, Marie Holmefur, Liselotte M N Hermansson.   

Abstract

BACKGROUND: The Orthotics and Prosthetics Users' Survey consists of five modules to assess outcomes of orthotic and prosthetic interventions: lower extremity functional status, upper extremity functional status, client satisfaction with device, client satisfaction with services and health-related quality of life.
OBJECTIVES: To investigate the test-retest reliability and calculate the smallest detectable difference for all modules of the Swedish Orthotics and Prosthetics Users' Survey. STUDY
DESIGN: Test-retest reliability study design.
METHODS: A total of 69 patients at a Department of Prosthetics and Orthotics completed Orthotics and Prosthetics Users' Survey on two occasions separated by a 2-week interval, giving 18 answers on lower extremity functional status, 41 on upper extremity functional status, 53 on client satisfaction with device, 12 on client satisfaction with services and 67 answers on health-related quality of life. Raw scores were converted into Orthotics and Prosthetics Users' Survey units on a 0-100 scale. Intra-class correlation coefficients, Bland-Altman plots, common person linking plots and t-tests of person mean measures were used to investigate the reliability. The 95% confidence level smallest detectable differences were calculated.
RESULTS: The intra-class correlation coefficients ranged from 0.77 to 0.96 for the modules, and no systematic differences were detected between the response occasions. The smallest detectable differences ranged from 7.4 to 16.6 units.
CONCLUSIONS: The test-retest reliability was satisfactory for all Orthotics and Prosthetics Users' Survey modules. The smallest detectable difference was large on all modules except the health-related quality of life module. CLINICAL RELEVANCE: The Orthotics and Prosthetics Users' Survey modules are reliable and, thus, can be recommended for repeated measurements of patients over time. Relatively large changes are needed to achieve statistical significance when assessing individual patients.

Entities:  

Keywords:  Outcome assessment; activities of daily living; quality of life; reproducibility of results

Mesh:

Year:  2013        PMID: 23652919     DOI: 10.1177/0309364613485113

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  6 in total

1.  Test-retest reliability of the Arabic translation of the Lower Extremity Functional Status of the Orthotics and Prosthetics Users' Survey.

Authors:  Ahmed Alhowimel; Faris Alodaibi; Khalid Al-Nowaisri; Mazyad Alotaibi; Haitham Ghazal
Journal:  Prosthet Orthot Int       Date:  2021-12-14       Impact factor: 1.672

2.  Home Use of a Neural-connected Sensory Prosthesis Provides the Functional and Psychosocial Experience of Having a Hand Again.

Authors:  Emily L Graczyk; Linda Resnik; Matthew A Schiefer; Melissa S Schmitt; Dustin J Tyler
Journal:  Sci Rep       Date:  2018-06-29       Impact factor: 4.379

3.  Validation of the Arabic version of the client satisfaction with device module of the orthotics and prosthetics users survey.

Authors:  Hadeel Bakhsh; Franco Franchignoni; Elisabetta Bravini; Giorgio Ferriero; Andrea Giordano; Calogero Foti
Journal:  Ann Saudi Med       Date:  2014 Jul-Aug       Impact factor: 1.526

4.  Satisfaction with ankle foot orthoses in individuals with Charcot-Marie-Tooth disease.

Authors:  Riccardo Zuccarino; Kirsten M Anderson; Michael E Shy; Jason M Wilken
Journal:  Muscle Nerve       Date:  2020-08-26       Impact factor: 3.217

5.  A modified walk-in system versus scheduled appointments in a secondary-care prosthetic and orthotic clinic.

Authors:  Gustav Jarl; Liselotte Hermansson
Journal:  Prosthet Orthot Int       Date:  2017-09-14       Impact factor: 1.895

6.  Learning of Artificial Sensation Through Long-Term Home Use of a Sensory-Enabled Prosthesis.

Authors:  Ivana Cuberovic; Anisha Gill; Linda J Resnik; Dustin J Tyler; Emily L Graczyk
Journal:  Front Neurosci       Date:  2019-08-21       Impact factor: 4.677