Optimisation of patient dose for the horizontal beam technique in lateral lumbar spine radiographic examinations.

A T Davis1, S A Hopkins.   

Abstract

In the emergency department, patients undergoing lateral lumbar spine radiography examinations are positioned either lying on their side on an X-ray table with the X-ray beam vertical or lying supine on a trolley with the X-ray beam horizontal. The measured dose-area product (DAP) values were found to differ significantly, typically 1.3 Gy cm(2) for those patients examined on the X-ray table and 2.7 Gy cm(2) for those on a trolley. This work investigates the reason for higher DAP values with the horizontal beam technique. The UK's current recommended national diagnostic reference level (NDRL) for the lateral lumbar spine is 2.5 Gy cm(2). The measurements of body diameter on volunteers showed that rotating the patients from their side to their back resulted in an increase in tissue thickness of between 2 cm and 9 cm for the lumbar region. X-ray absorption increases exponentially with increasing tissue thickness. An increase of 5 cm in body diameter for a lateral lumbar spine at 93 kV will increase the DAP by more than two-fold. Mathematical modelling and measurements with polymethyl methacrylate provided data to predict the tube potential increase necessary to reduce the DAP. For the horizontal beam technique, the tube potential was increased from 93 kV to 102 kV and the average DAP reduced to 2.3 Gy cm(2). Radiographic technique should be understood when auditing the dose. Tube potential must be increased to optimise the horizontal beam technique. The 2.5-Gy cm(2) NDRL relates predominantly to the more common vertical beam technique. Separate local diagnostic reference levels for horizontal and vertical beam techniques are recommended.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23652542      PMCID: PMC3922181          DOI: 10.1259/bjr.20130053

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  2 in total

1.  An instrumented phantom system for analog computation of treatment plans.

Authors:  S W ALDERSON; L H LANZL; M ROLLINS; J SPIRA
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1962-01

2.  Protocol for measurement of patient entrance surface dose rates for fluoroscopic X-ray equipment.

Authors:  C J Martin; D G Sutton; A Workman; A J Shaw; D Temperton
Journal:  Br J Radiol       Date:  1998-12       Impact factor: 3.039

  2 in total
  1 in total

1.  Effective dose and image optimisation of lateral lumbar spine radiography: a phantom study.

Authors:  Zer Hau Lai; Cláudia Sá Dos Reis; Zhonghua Sun
Journal:  Eur Radiol Exp       Date:  2020-02-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.